background image

Industrial Web-Smart High Power PoE Ethernet Switch

 

This quick start guide describes how to install and use the Industrial Web-Smart High Power PoE (Power 

over Ethernet) Ethernet Switch. This is the switch of choice for harsh environments constrained by space. 

 

Physical Description 

The Port Status LEDs and Power Inputs 

 

 

LED State 

Indication 

Steady Power 

on. 

Power1 
Power2 
Power3

 

Off Power 

off. 

Steady 

Power redundant system failure 
occurred.

 

Fault 

Off 

Power redundant system failure is 
not occurred.

 

10/100Base-TX, 100Base-FX/BX 

Steady 

A valid network connection 
established. 

Link/ACT

 

Flashing 

Transmitting or receiving data. 
ACT stands for ACTIVITY. 

Steady 

Valid port connection at 100Mbps. 

10/100 

Off 

Valid port connection at 10Mbps. 

Steady 

Powered Device (PD) is connected. 

PoE 

Off 

Powered Device (PD) is 
disconnected. 

 

 

Power Input Assignment 
Power3 55VDC 

DC 

Jack 

55VDC 

Power2

Power Ground

55VDC 

Power1

Power Ground

Earth Ground 

Terminal Block 

Relay Output Rating 

1A @ 24VDC 

Relay Alarm Assignment 

   

 
FAULT

*Relay warning signal disable for following: 
1. The relay contact closes if Power1 and 

Power2 are both failed but Power3 on. 

2. The relay contact closes if Power3 is failed 

but Power1 and Power2 are both on. 

 

The 10/100Base-TX and 100Base-FX/BX Connectors 

The 10/100Base-TX Connections 

The following lists the pinouts of 10/100Base-TX ports.

 

Pin PoE Ports (Port 1-4)

Non-PoE Port (Port 5) 

Output Transmit Data + Output Transmit Data + 

Output Transmit Data - Output Transmit Data - 

Input Receive Data + 

Input Receive Data + 

4 Positive 

(VCC+) 

 

5 Positive 

(VCC+) 

 

Input Receive Data - 

Input Receive Data - 

7 Negative 

(VCC-) 

 

8 Negative 

(VCC-) 

 

 

 

The 100Base-FX Connections

 

The fiber port pinouts 

The Tx (transmit) port of device I is connected to the Rx (receive) port of device II, 

and the Rx (receive) port of device I to the Tx (transmit) port of device II.

 

 

The WDM 100Base-BX Connections

 

The fiber port pinouts 

Only one optical fiber is required to transmit and receive data.

 

 

 

Functional Description 

 

Meets EN61000-6-2 & EN61000-6-4 EMC Generic Standard Immunity for industrial environment. 

 

Manageable via Web browser interface. 

 

Port 1 – 4 support Power over Ethernet (PoE) Power Sourcing Equipment (PSE). 

 

High Power PoE design up to 30W. 

 

Supports 802.3/802.3u/802.3x. Auto-negotiation: 10/100Mbps, full/half-duplex. Auto MDI/MDIX. 

 

100Base-FX: Multi mode/Single mode SC or ST type. 100Base-BX: WDM Multi mode/Single mode 

SC type. 

 

Supports 1024 MAC addresses. Provides 512K bits memory buffer. 

 

Alarms for power and port link failure by relay output. 

 

Power Supply: Redundant 55VDC Terminal Block power inputs and 55VDC DC JACK with optional 

100-240VAC external power supply. 

 

Operating voltage and Max. current consumption: 2.36A @ 55VDC. Power consumption: 130W 

Max. 

 -10

 

to 

60

 (

-14

 to 140

) operating temperature range. Tested for functional operation @ 

-20

 to 

70

 (

-4

 to 158

). 

 

Supports Wall and Desktop Mounting installation. 

1                                                                                                                                                      V2 

Отзывы: