Unpacking 

Unpack the items. Your package should include: 

 

One EX17908A unmanaged switch 

 

One external power adapter 

 

One CD containing this user’s guide 

If items are missing or damaged, notify your 
EtherWAN representative. Keep the carton and 
packing material. 
 

What Else You Need 

 

Category 5 or better Ethernet cables 

 

Select a Location 

 

Desktop installations: Mount on a flat table 
or shelf surface. 

 

Rack installations: Use a 19-inch (48.3-
centimeter) EIA standard equipment rack 
that is grounded and physically secure.  

 

Identify a power source within 6 feet (1.8 
meters). 

 

Choose a dry area with ambient temperature 
between 0 and 40ºC (32 and 104ºF). 

 

Do not cover fans on the rear and side. 

 

Keep away from heat sources, sunlight, warm 
air exhausts, hot-air vents, and heaters. 

 

Be sure there is adequate airflow. 

 

Keep the switch at least 6 ft (1.83 m) away 
from the nearest source of electromagnetic 

noise, such as a photocopy machine. 
 

Connect to the Data Ports 

 

The switch provides eight 10/100/1000 Mbps RJ-
45 ports that can connect to Power over 
Ethernet (PoE) devices, such as an IP surveillance 
camera or a Voice Over Internet Protocol (VoIP) 
phone. 

A.

 

Insert one end of a Category 5 or better 
Ethernet cable into a switch port.  

B.

 

Connect the other end into the Ethernet port 
of the device.  

C.

 

Repeat steps A and B for each additional 
device you want to connect to the switch. 
 

Apply AC Power 

A.

 

Connect the female end of the supplied AC 
power adapter cable to the power receptacle 
on the switch rear panel. Connect the other 
end to a grounded 3-pronged AC outlet. 

B.

 

On the switch rear panel, move the ON/OFF 
switch to the ON position. 

 

When you apply AC power: 

 

All green 

PoE 

and 

Link/ACT

 LEDs blink 

momentarily. 

 

The fans start. 

 

The yellow 

Power 

LED goes ON.  

 

The 

Link/ACT

 LEDs for every port connected 

to a device flash, as the switch conducts a 
brief Power On Self-Test (POST). 

Front Panel LEDs 

 

LED 

Color  Status 

Power 

Yellow  ON = switch is receiving power. 

PoE

 

(port number)

 

Green  ON = Power Device (PD) is connected. 

OFF = PD is disconnected. 

Link/ACT

 

(port number)

 

Green 

ON = valid network connection. 

OFF = no data transmission on port. 

Flashing = port is sending or receiving 

data. 

 

 

Congratulations! 

You have successfully 

installed your switch.

 

 

EX17908A Unmanaged Switch Installation Guide 