Страница 1: ...Eteirn 1 Lighting STELLAR6OXT 60 Watt LED Moving Head ...

Страница 2: ...TIONS 11 CONFIGURING THE STARTING ADDRESS 11 CONTROL PANEL FUNCTIONS 11 MENU MAP 12 DMX OPERATION 13 STANDALONE OPERATION 13 AUTOMATIC FAST 13 AUTOMATIC SLOW 13 SOUND ACTIVE 13 CHANNEL 13 DEGREE 14 REVERSAL 14 RESET 14 LOAD DATA 14 MASTER SLAVE 15 DMX CHANNEL VALUES 16 5 APPENDIX 18 DMX PRIMER 18 GENERAL MAINTENANCE 18 FIXTURE LINKING 19 DATA CABLING 19 DMX DATA CABLE 19 CABLE CONNECTORS 19 3 PIN ...

Страница 3: ...10 A LCD display to be configured Menu A key to be pressed on the fixture s control panel 1 512 A range of values 50 60 A set of values of which only one can be chosen Settings A menu option not to be modified for example showing the operating mode current status MENU Settings A sequence of menu options to be followed ON A value to be entered or selected Icons This manual uses the following icons ...

Страница 4: ...e sure that no ventilation slots are blocked Always disconnect from power source before servicing or replacing fuse and be sure to replace with same fuse source Secure fixture to fastening device using a safety chain Maximum ambient temperature Ta is 104 F 40 C Do not operate fixture at temperatures higher than this In the event of a serious operating problem stop using the unit immediately Never ...

Страница 5: ...e electronic dimmer 0 100 Remote fixture reset vector speed channel Individual reset of pan tilt color gobo prism focus Move in black for pan tilt color gobo Built in movement macros via DMX automated and sound Additional Features Built in automated programs viamaster slave Built in sound active programs via master slave High power 60 W 13 5 A LED User selectable pan tilt ranges Pan 540 360 180 Ti...

Страница 6: ...2 Introduction ...

Страница 7: ...IFront lens Tilt Pan Control I Panel Standing feet I DMX IN Power Fuse Holder ...

Страница 8: ...re to a rheostat variable resistor or dimmer circuit even if the rheostat or dimmer channel is used only as a 0 to 100 switch Always connect the fixture to a circuit with a suitable electrical ground The maximum quantity of fixtures that may be linked is 4 Power Linking This fixture contains power linking via the edison outlet located in front of the power input cable Please see the diagram below ...

Страница 9: ...tion Third fixture Second fixture First fixture DMX controller Only in DMX operation Additional sianal DMX link out Fuse Replacement A replace with the same type fuse Disconnect the power cord before replacing a fuse and always With a flat head screwdriver unscrew the fuse holder out of its housing turning counter clockwise Remove the damaged fuse from its holder and replace w ith exact same type ...

Страница 10: ... size When rigging consider routine maintenance and control panel access Please see the following steps for installation If the power link out is intended to be used with multiple fixture take into account the length of each power cable and mount the fixtures close enough to one another to accommodate for this Attach both included bolts in the locations indicated below using a metric 8 mm Allen wr...

Страница 11: ... If this is your first time using DMX we recommend reading the DMX Primer section in the Appendix Control Panel Functions Access control panel functions using the four buttons located directly underneath the LED display on the included wired remote BUTTON FUNCTION Used to scroll through the current operating mode as well as back out of the current menu option Used to select decreasing advancement ...

Страница 12: ...ction Standalone Studio mode display Slave Standalone Slave selection Sets the fixture to respond to another fixture set to master Reversal Pan Normal Pan Norman Scan Reversal Pan Reversal Scan Tilt Normal Tilt Norman Scan Reversal Tilt Reversal Scan Degree Pan 540 Pan 540 360 Pan 360 180 Pan 180 Tilt 270 Tilt 270 180 Tilt 180 90 Tilt 90 Channel 15CH Channel Personality Advanced 10CH Channel Perso...

Страница 13: ...el ect AUTO FAT 4 Press ENTER Automatic Slow This fixture has preprogrammed slow chases These are accessed via the control panel Please see the Instructions Below for further explanation 1 Press MENU using UP and DOWN select until INSET appears on the LCD screen 2 Press ENTER 3 Select AUTOSLOW 4 Press ENTER Sound Active This fixture has preprogrammed sound triggered chases These are accessed via t...

Страница 14: ...ppears on the LCD screen 2 Press ENTER 3 Using UP and DOWN Select PAN or TILT 4 Press ENTER Using UP and DOWN Select degree PAN nomal reversal or TILT nomal reversal 5 Press ENTER Reset This fixture has preprogrammed reset triggered chases These are accessed via the control panel Please see the Instructions Below for further explanation 1 Press MENU using UP and DOWN select until Reset appears on ...

Страница 15: ... operation Please see the diagram below on the connections for your fixtures as well as the setting to assign in the control panel B it is not necessary to arrange the master fixture as the first fixture in the daisy chain It may be any fixture in the daisy chain For example fixture 2 5 10 or 12 etc Only 1 fixture may be set to master Do not connect a DMX controller to the daisy chain for this ope...

Страница 16: ... counter clockwise with increasing speed 8 Gobo Rotation 000 009 NO Function 010 116 Rotate clockwise slow fast 117 244 Rotate counterclockwise slow fast 245 255 Gobo bounce CHANNEL VALUE FUNCTION 9 Gobo Wheel 2 000 018 White 019 037 Gobo 1 038 056 Gobo 2 057 075 Gobo 3 076 094 Gobo 4 095 113 Gobo 5 114 127 Gobo 6 128 191 Rotating clockwise with increasing speed 192 255 Rotating counter clockwise ...

Страница 17: ...obo 3 076 094 Gobo 4 095 113 Gobo 5 114 127 Gobo 6 128 191 Rotating clockwise with increasing speed 192 255 Rotating counter clockwise with increasing speed 8 Gobo Rotation 000 009 NO Function 010 116 Rotate clockwise slow fast 117 244 Rotate counter clockwise slow fast 245 255 Gobo bounce CHANNEL VALUE FUNCTION 9 Gobo Wheel 2 000 018 White 019 037 Gobo 1 038 056 Gobo 2 057 075 Gobo 3 076 094 Gobo...

Страница 18: ... to female connectors The shield connection is pin 1 while pin 2 is Data Negative S and pin 3 is Data positive S General Maintenance To maintain optimum performance and minimize wear fixtures should be cleaned frequently Usage and environment are contributing factors in determining frequency As a general rule fixtures should be cleaned at least twice a month Dust build up reduces light output perf...

Страница 19: ...xtures on a serial data link 32 Data Cabling To link fixtures together you must obtain data cables You can purchase certified DMX cables directly from a dealer distributor or construct your own cable If you choose to create your own cable please use data grade cables that can carry a high quality signal and are less prone to electromagnetic interference DMX Data Cable Use a Belden 9841 or equivale...

Страница 20: ...the input connector of the next fixture consisting of a male 3 pin connector 3 Then proceed to connect from the output as stated above to the input of the following fixture and so on Setting the Starting Address This DMX mode enables the use of a universal DMX controller device Each fixture requires a start address from 1 512 A fixture requiring one or more channels for control begins to read the ...

Страница 21: ...ged DMX cables Wrong polarity settings on the controller Loose DMX cables Faulty DMX interface Faulty Main PCB Check Control Panel and unit addressing Check DMX cables Check polarity switch settings on the controller Check cable connections Replace DMX input Replace Main PCB Loss of signal Non DMX cables Bouncing signals Long cable Low level signal Too many fixtures Interference from AC wires Use ...

Страница 22: ...nrush Power Consumption 230 VAC 50 Hz 144 W 0 5 A max 1 A inrush Power output 4 units max Fuse F 2 A 250 V LIGHT SOURCE LED 1 white 60 W 13 5 A 50 000 hrs PHOTOOPTIC Luminance 1 m 18 000 lux Beam Angle 14 GOBOS Outside diameter 23 8 mm Image diameter 20 mm Maximum thickness 2 mm THERMAL Maximum ambient temperature 104 F 40 C WARRANTY INFORMATION Warranty 1 year limited warranty Technical Specifica...