SAFETY AND INSTALLATION INSTRUCTIONS
111220-SM
HELpLINE:
• T: 01933 673 144
• F: 01933 678 083
• E: [email protected]
Visit our website:
www.eterna-lighting.co.uk
Pack contents:
1 x fitting
2 x 26W compact
fluorescent lamps
Model:
SL226W & SL226WPC
2 x 26W Low Energy Floodlight /
2 x 26W Low Energy Floodlight with Photocell
These instructions are provided as a guideline to assist you.
PLEASE READ THESE INSTRUCTIONS BEFORE USING YOUR NEW FITTING
pLEASE RETAIN FOR FUTURE REFERENCE
ENERgY INFORmATION:
LAmp REpLACEmENT:
• Switch off the electricity at the mains.
• Release the front cover by unscrewing the 4 fixing
screws, taking care not to lose the “O” rings.
• Remove the lamp by pulling gently away from the
lampholder and lifting free.
• Fit replacement lamp by pushing it into the
lampholder and refit the front cover.
REpLACEmENT LAmp TYpE:
Wattage: 26W
Supply Voltage: 230V
Type: G24q-3 Double Turn D 4 Pin CFL
EvENTUALLY, YOU mAY WANT TO
REpLACE THIS pRODUCT:
Regulations require the recycling of Waste from
Electrical and Electronic Equipment (European
“WEEE Directive” effective August 2005—UK
WEEE Regulations effective 2nd January 2007).
Environment Agency Registered Producer: WEE/
GA0248QZ.
WhEn yoUR PRoDUCT ComES To ThE EnD oF
iTS LiFE oR yoU ChooSE To REPLACE iT, PLEASE
RECyCLE iT WhERE FACiLiTiES ExiST - Do noT
DiSPoSE WiTh hoUSEhoLD WASTE.
IF YOU ExpERIENCE pRObLEmS:
if you believe your product is defective, please
return it to the place where you bought it.
Our Technical Team will gladly advise on any
Eterna Lighting product, but may not be able to
give specific instructions regarding individual
installations.
If in doubt, consult a qualified electrician.
Lamp Information
A
B
C
D
E
F
G
b
1716
Lumen
26 Watt
8000
hours
26W Fluorescent
Rated lamp efficacy at 100 hours in standard
conditions: >50 hz • 1716 Lumen
The power dissipated by the auxiliary
equipment such as ballasts is not included in
the power consumed by the source.
Rated lamps Lumen maintenance Factor
(testing mode 50 Hz):
2 000 h ≥ 100%
4 000 h ≥ 97%
6 000 h ≥ 96%
8 000 h ≥ 81%
Rated lamp Survival Factor
(testing mode 50 Hz):
2 000 h ≥ 99%
4 000 h ≥ 98%
6 000 h ≥ 95%
8 000 h ≥ 87%
• Lamp mercury content:
2.0mg
• Colour rendering index (Ra):
> 80
• Colour temperature of the lamp:
6400 K
• Lamp efficacy:
66 Lm/W
• Ballast efficiency:
EEi = A2