[email protected] • (855) 686-3835

TENS Unit

User Manual

Model:

 ETU-134

Содержание ETU-134

Страница 1: ...1 Questions or Concerns support etekcity com 855 686 3835 TENS Unit User Manual Model ETU 134 ...

Страница 2: ...questions or concerns please reach out to our helpful Customer Support Team at support etekcity com We hope you enjoy your new TENS unit BECOME AN ETEKCITIZEN Get exclusive deals giveaways and product registration Better products for better living Find us at etekcity com ...

Страница 3: ...Using the TENS Unit Electrode Placement Guide Treatment Maintenance Troubleshooting Glossary of Symbols Warranty Information Customer Support 3 4 6 11 12 13 14 14 15 16 16 19 21 24 27 37 39 1 x TENS Unit 2 x Electrode Pads 40 x 40 mm 4 x Electrode Pads 50 x 50 mm 2 x Electrode Pads 50 x 100 mm 4 x Lead Wires 1 x Micro USB Cable 1 x User Manual 1 x Quick Start Guide Package Contents ...

Страница 4: ... Operation Time 10 60 minutes Dimensions 5 5 x 2 5 x 0 6 in 138 8 x 63 3 x 15 5 mm Weight 3 2 oz 96 g Operating Environment Temperature 41 F 104 F 5 C 40 C Relative Humidity 30 75 Atmospheric Pressure 700hPa 1060hPa Transport and Storage Environment Temperature 14 F 131 F 10 C 55 C Relative Humidity 10 90 Air Pressure 700hPa 1060hPa Specifications ...

Страница 5: ...ttery Type 3 7V 250mAh Li ion battery Rated Power 4 2V Charging Time 3 hours Automatic Shutoff 3 minutes Service Life TENS Unit 3 years Electrodes 10 15 uses IP Code IP22 Classification of ME Equipment Internally powered operating Class II charging Continuous operation ...

Страница 6: ...ructions and safety guidelines in this manual You should consult your physician if You have never used a TENS unit before The TENS unit may cause lethal disturbances to heart rhythm in certain individuals You have had or are using medical or physical treatment for your pain Your pain worsens or continues for more than 5 days You experience adverse reactions from the TENS unit Do not use the TENS u...

Страница 7: ...r swollen red infected or inflamed areas or skin eruptions e g phlebitis thrombophlebitis varicose veins Warnings cont Do not use the TENS unit over or close to cancerous lesions Do not place the electrodes inside body cavities such as the mouth This may cause irritation burns or electric shock The TENS unit is not designed for internal application Do not use the TENS unit in the presence of elect...

Страница 8: ... treatment may not be effective for everyone Consult your physician or healthcare professional to find out if TENS will work for you The long term effects of electrical stimulation are unknown Because the effects of electrical stimulation on the brain are unknown do not use the TENS unit on your head Electrical stimulation and the pads conductive gel may cause skin irritation or hypersensitivity T...

Страница 9: ...on both legs or feet at the same time Only treat 1 at a time Precautions cont General Recommendations Do not use the TENS unit for any other purpose than what it is intended for The TENS unit is designed for use by a single adult person For hygienic reasons electrodes should not be shared Do not use the TENS unit if you are connected to high frequency surgical equipment This may result in burns on...

Страница 10: ...unit only treats symptoms It reduces the feeling of pain but it does not cure the cause of the pain Pain may be a signal from your body that some part of your body is damaged and needs attention You may get skin irritation and burns on the skin under the electrodes You may get a headache or other pain if you use the TENS unit near your eye or on your head or face You may experience muscle exhausti...

Страница 11: ...ty Increase Decrease C Therapy Modes 15 D Time Button E Lead Wires F Battery Indicator G B Channel Intensity Increase Decrease H Power Pause Button I A1 Output J A2 Output K Micro USB Port L B1 Output M B2 Output N Electrode Pad O Micro USB Cable Function Diagram ...

Страница 12: ...A Time Display B A Channel Intensity Level C Body Part Icons D Program Number E Pause Icon F B Channel Intensity Level G Kneading Icon H ACU Acupuncture Icon I Tap Icon J Cupping Icon K Scraping Icon L Random Icon Digital Display ...

Страница 13: ...mode at a time The TENS unit will automatically default to the last mode selected Body Part Press to select which area of the body to focus on The selection will flash on the display and show the corresponding number Massage Type Press to select the massage type The selection will flash on the display and show the corresponding number 1 Neck 2 Shoulder 3 Back 10 Knead 11 ACU 4 Elbow 5 Hip 6 Ankle ...

Страница 14: ...remities arm and lower extremities leg due to strain from exercise or normal household work activities It should be applied to normal healthy and dry skin of adult patients The TENS unit works best on acute pain because it is localized Acute pain occurs in 1 area for less than 3 months If you have chronic pain often including experiencing pain in more than 1 area and for longer than 6 months then ...

Страница 15: ...for a short period of time Use caution when working with higher intensities at the limit of what you can tolerate Do not exceed your comfort level Length and Intensity Stop using the TENS unit if Pain has reduced or stopped You experience an adverse reaction such as skin irritation redness burns headaches other painful sensations or any increased discomfort Your pain becomes chronic and severe or ...

Страница 16: ...ever remove the self adhesive pads from the skin while the TENS unit is turned on Note Before first use fully charge the TENS unit see Charging the Battery page 21 Electrode Placement Guide Hip Pain in the hip area is often the result of wearing of the joints arthrosis Pain in the hip region may be treated with the application of electrodes above and below the joint In addition pain may also radia...

Страница 17: ...Attach both sets of electrodes on either side of the joint where you feel pain Neck Attach both sets of pads to the back of the neck Do not place on carotid artery or throat Lower Back Lumbar Attach both sets of electrodes to the lower back with the backbone in the center Do not place on the backbone or spine Upper Back Attach both sets of electrodes to the upper back with the backbone in the cent...

Страница 18: ...or leg where you feel pain Ankle Foot For pain on the outside of the ankle or foot attach electrodes above and below the pain point For pain on the inside of the ankle or foot attach 1 electrode above the ankle and 1 in the center of the sole of your foot Note Do not place electrodes on both legs or feet at the same time Only treat 1 at a time Only place electrodes according to Electrode Placement...

Страница 19: ...nt 2 Insert the lead wire plugs into the sockets on the TENS unit You can use up to 4 3 Press to turn on the TENS unit Wait 2 seconds for the TENS unit to fully turn on 4 Select 1 of 15 therapy modes The selected icon will flash on the screen and show the corresponding number Note This TENS unit has 4 independent channels A1 A2 B1 B2 Make sure you know which channel s you want to use before you co...

Страница 20: ...screen The default time is 20 minutes 6 Press or to begin the treatment Press again to increase the intensity Note Intensity can be adjusted independently for A and B channels Press repeatedly on the left side and right side to raise or lower intensity for channel A A1 and A2 output and channel B B1 and B2 output Lowering both intensities to 0 will reset the timer Caution Do not remove electrode p...

Страница 21: ... is about 3 hours For best results fully charge your TENS unit before using The battery indicator will flash Warning If batteries leak and come into contact with skin or eyes wash immediately with water The life of any rechargeable battery depends on the number of recharge rundown cycles it undergoes and how these cycles are performed The service life of the rechargeable battery is more than 300 r...

Страница 22: ...air dry completely Cleaning the TENS Unit Cleaning the Electrode Pads Note Do not use chemicals or detergents to clean the unit Do not let water get into the TENS unit The TENS unit and the accessories do not require sterilization Note Do not use chemicals detergents or soap to clean the electrode pads Do not use a sponge cloth or any sharp object on the adhesive side of the pads Wash the pads whe...

Страница 23: ...t are larger may reduce the effect of the stimulation while smaller electrodes may increase the chance of skin irritation or burns Turn the device off and remove lead wires from the TENS unit Place the pads on the plastic film wrap the lead wires and store in a sealed package Store in a dry clean place Do not store in extreme temperatures Storage environment should be 14 F 131 F 10 C 55 C 10 90 RH...

Страница 24: ...irty Wash or replace with new pads Lead wire may be old worn or damaged Stop using and contact Customer Support see page 39 Electrical stimulation is uncomfortable Intensity is too high Lower the intensity see Using the TENS Unit page 16 Electrode pads may be too close together Reposition them at least 2 in 5 cm apart Electrode pads may be too small Replace with pads that have a diameter no smalle...

Страница 25: ...e electrodes Contact your physician or medical practitioner Skin turns red or there is a stabbing pain Using electrodes on the same area every time can cause discomfort Reposition the electrodes see Electrode Placement Guide page 16 Stop using immediately if you feel any more pain or discomfort The electrodes may be damaged dirty or may not be attached to the skin properly Make sure they are clean...

Страница 26: ...ontinue the treatment Make sure the lead plug is inserted into the correct output socket Charge the TENS unit Lead wires may be damaged Stop using and contact Customer Support see page 39 The TENS unit runs out of battery too quickly or does not hold any charge Contact Customer Support see page 39 If your problem is not listed please contact Customer Support see page 39 ...

Страница 27: ...econd number 2 Protected against vertically falling water drops when tilted up to 15 Type BF Applied Part The applied part is the electrode Refer to instruction manual Date of manufacture IP22 B N Transportation and storage temperature from 14 F 131 F 10 C 55 C Transportation and storage humidity limits from 10 90 Transportation and storage atmospheric pressure limits from 700hPa 1060hPa The first...

Страница 28: ...nt adjacent to or stacked with other equipment should be avoided because it could result in improper operation If such use is necessary this equipment and the other equipment should be observed to verify that they are operating normally Portable RF communications equipment including peripherals such as antenna cables and external antennas should be used no closer than 12 in 30 cm to any part of th...

Страница 29: ...y be affected as follows The device stops output The device turns off The device restarts The above will not affect the basic safety and essential performance of the device and the user can use it according to the instructions If you want to avoid this please use it according to the environment requirements specified in the manual ...

Страница 30: ...uses RF energy only for its internal function Therefore its RF emissions are very low and are not likely to cause any interference in nearby electronic equipment RF emissions CISPR 11 Class B The device is suitable for use in all establishments including domestic establishments and those directly connected to the public low voltage power supply network that supplies buildings used for domestic pur...

Страница 31: ...V air Floors should be wood concrete or ceramic tile If floors are covered with synthetic material the relative humidity should be at least 30 Electrical fast transient burst IEC 61000 4 4 2 kV for power supply lines 1 kV for input output lines 2 kV for power supply lines 1 kV for input output lines Mains power quality should be that of a typical commercial or hospital environment Surge IEC 61000 ...

Страница 32: ...er quality should be that of a typical commercial or hospital environment If the user of the device requires continued operation during power mains interruptions it is recommended that the device be powered from an uninterruptible power supply or a battery Power frequency 50 60 Hz magnetic field IEC 61000 4 8 30 A m 30 A m Power frequency magnetic fields should be at levels characteristic of a typ...

Страница 33: ...e and mobile RF communications equipment should be used no closer to any part of the device than the recommended separation distance calculated from the equation applicable to the frequency of the transmitter Recommended separation distance d 1 2 P 150 KHz to 80 MHz d 1 2 P 80 MHz to 800 MHz d 2 3 P 80 MHz to 2 7 GHz where P is the maximum output power rating of the transmitter in watts W accordin...

Страница 34: ...mobile radios amateur radio AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy To assess the electromagnetic environment due to fixed RF transmitters an electromagnetic site survey should be considered If the measured field strength in the location in which device is used exceeds the applicable RF compliance level above device should be observed to verify no...

Страница 35: ...nterference by maintaining a minimum distance between portable and mobile RF communications equipment transmitters and device as recommended below according to the maximum output power of the communications equipment Rated maximum output power of transmitter W Separation distance according to frequency of transmitter m 0 15 MHz to 80 MHz d 1 2 P 80 MHz to 800 MHz d 1 2 P 80 MHz to 2 7 GHz d 2 3 P ...

Страница 36: ...quency of the transmitter where P is the maximum output power rating of the transmitter in watts W according to the transmitter manufacturer Note 1 At 80 MHz and 800 MHz the higher frequency range applies Note 2 These guidelines may not apply in all situations Electromagnetic propagation is affected by absorption and reflection from structures objects and people Table 4 cont ...

Страница 37: ...se or use noncompliant with the user manual or any additional safety or use warnings included in the product packaging and manual This warranty does not apply to the following Damage due to abuse accident alteration misuse tampering or vandalism Improper or inadequate maintenance Damage in return transit Unsupervised use by children under 18 years of age Etekcity Corporation and its subsidiaries a...

Страница 38: ...of purchase and purchase date if applicable Defective Products Returns If you discover your product is defective within the specified warranty period please contact Customer Support via support etekcity com with a copy of your invoice and order ID DO NOT dispose of your product before contacting us Once our Customer Support Team has approved your request please return the product with a copy of th...

Страница 39: ...tomer Support Team Your satisfaction is our goal Customer Support Distributed by Etekcity Corporation 1202 N Miller St Suite A Anaheim CA 92806 Email support etekcity com Toll Free 855 686 3835 Support Hours Monday Friday 9 00 am 5 00 pm PST PDT Please have your invoice and order ID ready before contacting Customer Support ...

Страница 40: ...40 Notes ...

Страница 41: ...41 Notes ...

Страница 42: ...42 Notes ...

Страница 43: ...43 Connect with us Etekcity ...

Страница 44: ...Building on better living V1 0_20190621 ...