background image

E T C   I n s t a l l a t i o n   G u i d e

Unison Heritage Button Station

Unison  Heritage  Button  Station

 Page 1 of 4

Electronic Theatre Controls, Inc.

Corporate Headquarters

 

 3031 Pleasant View Road, P.O. Box 620979, Middleton, Wisconsin 53562-0979 USA 

 Tel +608 831 4116 

 Fax +608 836 1736

London, UK

 

 Unit 26-28, Victoria Industrial Estate, Victoria Road, London W3 6UU, UK 

 Tel +44 (0)20 8896 1000 

 Fax +44 (0)20 8896 2000

Rome, IT 

 

Via Pieve Torina, 48, 00156 Rome, Italy 

 Tel +39 (06) 32 111 683 

 Fax +44 (0)20 8752 8486

Holzkirchen, DE

 

 Ohmstrasse 3, 83607 Holzkirchen, Germany 

 Tel +49 (80 24) 47 00-0 

 Fax +49 (80 24) 47 00-3 00

Hong Kong 

 Rm 1801, 18/F, Tower 1 Phase 1, Enterprise Square, 9 Sheung Yuet Road, Kowloon Bay, Kowloon, Hong Kong 

 Tel +852 2799 1220

Service: 

(Americas)

 [email protected]

 

 

(UK)

 [email protected]

 

 (DE)

 [email protected]

 

 

(Asia)

 [email protected]

Web:

 www.etcconnect.com

 

 Copyright © 2012 ETC. All Rights Reserved. 

 Product information and specifications subject to change.

7181M2100

 

 Rev D 

 Released 2012-02 

 ETC intends this document to be provided in its entirety.

Overview

The Unison

®

 Heritage Button Station connects to the LinkConnect station 

communication bus. LinkConnect is based on Echelon

®

 LonWorks™ with 

LinkPower bidirectional protocol, and uses one pair of wires (data+, data–).

LinkPower is topology free and polarity independent; you can install your 
LinkPower data runs in any desired combination of bus, star, loop, and home-run. 
ETC recommends using Belden 8471 (or approved equal) wire. The total 
combined length of a LinkPower wire run may not exceed 1,640 feet (500m), with 
a maximum distance of 1,312 feet (400m) between any two devices. The Heritage 
Button Station may be installed into an industry standard single gang backbox 
(provided by others) or a surface mounted backbox (sold separately and available 
from ETC). 

All control wiring should be installed and terminated by a qualified installer and 
should follow standard wiring installation practices. Leave approximately 10 inches 
(254mm) of wiring in the backbox for connection and to allow slack for future 
service needs.

Installing the Heritage Button Station

Installation should follow local codes 
and standard practices. The backbox 
should be installed square for best 
results. Ensure that the backbox is clean 
and free of obstructions and that all 
wiring is installed correctly.

Heritage stations ship with a termination 
kit containing a LinkPower pigtail, a 
ground wire pigtail, spacers, and all 
required connectors for installation. 

Heritage Button Station Surface Backbox

Model

Description

-1S

Unison 1Gang surface mount backbox

-2S

Unison 2Gang surface mount backbox

N o t e :

ETC requires that all stations be grounded by using grounded 

metal conduit or a 14 AWG (2.5mm

2

) ESD drain wire.

LinkPower 

pigtail

Ground

pigtail

WAGO

Spacers