TurboRay User Manual
Install the Fixture
WARNING:
•
The installation location must support a minimum point load of 10
times the weight of the fixture.
•
The installation must always be secured with a secondary safety
attachment. An appropriate safety cable is supplied.
•
Safety cable attachment must be rated by a safety factor of 10.
•
Use of third party clamps are permitted, but they should comply with,
and be approved by, the Authority Having Jurisdiction (AHJ).
•
A supportive and stable surface must be used when the fixtures are
placed on the feet.
•
The operating temperature range for this fixture is 0-40°C. Do not
operate the fixture outside of this range.
•
Never stand directly below the installed fixture when mounting,
removing, or servicing the fixture.
•
All safety and technical aspects of fixture installation must be
approved by a qualified personnel before operation.
•
The installation must be regularly inspected by qualified personnel.
•
Overhead rigging must be performed by qualified personnel.
CAUTION:
Follow all local codes and recommended practices by the
Authority Having Jurisdiction. The installation must only be carried out by
qualified personnel.
You can install the fixture in any of the orientations shown below.