ETC SolarFrame 750 Скачать руководство пользователя страница 1

High End Systems

SolaFrame 750

Automated Luminaire User Manual

Version 1.2.11

Part Number: 2560M1200-1.2.11 Rev: A

Released: 2021-06

Содержание SolarFrame 750

Страница 1: ...High End Systems SolaFrame 750 Automated Luminaire User Manual Version 1 2 11 Part Number 2560M1200 1 2 11 Rev A Released 2021 06 ...

Страница 2: ...arks both marked and not marked are the property of their respective owners You can find complete High End Systems terms and conditions and warranty information at etcconnect com Support Warranty aspx ETC intends this document whether printed or electronic to be provided in its entirety ...

Страница 3: ...delines 5 Fixture Overview 6 Install the Fixture 7 Power 10 Electrical Specifications 10 Input and Power Factor 10 Connector Specification 10 DMX Control 11 DMX Connector Pinout 11 Connect DMX Cables to Fixture 12 DMX Control and Ethernet Output 12 Terminate DMX 12 Set the DMX Start Address 13 DMX Channels 13 Ethernet Control 13 Connect Ethernet Cables to a Fixture 13 ...

Страница 4: ... 14 Configure the Fixture 15 Navigate the User Interface 15 Set Fixture Parameters 16 DMX Address 16 Info Menu 16 Set Menu 18 Test Menu 21 Preset Menu 21 Error Codes 22 Maintenance 24 Clean the Fixture 24 Replace the Fuse 24 Compliance 25 FCC Compliance 25 Declarations of Conformity 26 ii SolaFrame 750 User Manual ...

Страница 5: ...tant messages Note Notes are helpful hints and information that is supplemental to the main text CAUTION Hot Surfaces This statement indicates that while operating equipment surfaces may reach very high temperatures Allow the fixture to cool before handling or servicing CAUTION A Caution statement indicates situations where there may be undefined or unwanted consequences of an action potential for...

Страница 6: ...Middleton WI 53562 800 775 4382 USA toll free 1 608 831 4116 service etcconnect com ETC GmbH Germany Austria Switzerland Eastern Europe and Russia Technical Services Department Ohmstrasse 3 83607 Holzkirchen Germany 49 80 24 47 00 0 techserv germany etcconnect com ETC Austin High End Systems Products Technical Services Department 2105 Gracy Farms Lane Austin TX 78758 USA 800 890 8989 USA toll free...

Страница 7: ...waste but must be sent to separate collection facilities for recovery and recycling Ce produit ne doit pas être jeté avec les déchets ménagers mais doit être déposé dans une collecte de déchets électroniques ou dans un point de collecte Operate indoors only not where this product would be exposed to the weather Ne fonctionne qu à l intérieur pas là où ce produit serait exposé aux intempéries WARNI...

Страница 8: ... entre la tête du luminaire et les matériaux combustibles 0 5 m 1 ft 8 in Distance minimale avec les objets éclairés 1 5 m 4 ft 11 in WARNING RISK OF ELECTRIC SHOCK Do not operate this device with the cover open Disconnect the fixture from power and DMX and allow it to cool before performing any cleaning and maintenance AVERTISSEMENT RISQUE DE CHOC ÉLÉCTRIQUE N utilisez pas cet appareil avec le co...

Страница 9: ... a complete 90 degree positive latch Operate the fixture only after having familiarized yourself with its functions Do not permit persons who are not qualified and familiar with its functions to operate the fixture Do not modify the fixture Any modifications will void the warranty This manual describes the proper installation and operation of this fixture Using this fixture in any way other than t...

Страница 10: ...ture see the technical datasheet etcconnect com Products High End Systems Lighting Fixtures SolaFrame 750 Documentation aspx 2 5 6 7 1 4 8 9 10 3 1 Lens 2 Tilt lock 3 Pan lock 4 Display 5 Navigation controls 6 Enclosure handle 7 Fuse 8 Power In and Power Out 9 DMX In and DMX Out 10 Ethernet ports x2 ...

Страница 11: ...ied personnel AVERTISSEMENT Boîtier NEMA de type 1 utilisation en intérieur emplacements secs uniquement Ne l utilisez pas en extérieur Ce projecteur est conçu pour être utilisé dans des environnements où l humidité ne dépasse pas 90 sans condensation La plage de température de fonctionnement de ce projecteur est de 0 C 45 C 32 F 113 F Ne faites pas fonctionner le projecteur audelà de cette plage ...

Страница 12: ...tion The installation must only be carried out by qualified personnel ATTENTION Respectez tous les règlements locaux et toutes les pratiques recommandées par l autorité compétente L installation doit être effectuée uniquement par du personnel qualifié You can install the fixture in any of the orientations shown below ...

Страница 13: ...secured 4 Repeat steps 1 through 3 for the second clamp and bracket 5 Attach the provided safety cable through the attachment point on the bottom of the fixture upper enclosure and secure to the trussing system or other safe installation point Follow local codes and recommended safety standards for securing the fixture to the installation location 6 Attach the fixture to the installation location ...

Страница 14: ...m potential draw before you connect it Connector Specification WARNING Risk of Shock and Fire Assemble a grounding type attachment plug with integral cord grip that is within the voltage and amperage rating of this luminaire AVERTISSEMENT Risque de choc et d incendie Assurez vous d utiliser une prise de mise à la terre avec décharge de traction intégrée qui respecte la tension et l ampérage de ce ...

Страница 15: ...rmination receptacles are available one for connection of DMX Input and one for DMX Out used when daisy chaining to additional fixtures on the DMX control bus DMX Connector Pinout For DMX Input the DMX cable must have a XLR plug connector on one end of the cable that connects to the fixture When daisy chaining DMX to the next device prepare a DMX cable with a XLR socket connector on one end and a ...

Страница 16: ...lden 9729 or equivalent terminate DMX with a 120 Ohm resistor DMX 512 control source DMX Control and Ethernet Output You can use DMX 512 control and Ethernet output When a fixture is set up to receive DMX 512 control input it converts the signal to Art Net on IP10 and sends the signal to the Ethernet port continuing the Art Net on IP10 signal to the next fixture in the control run Terminate DMX Us...

Страница 17: ...es two Ethernet ports that allow sending and receiving of control signals using the Art Net protocol or sACN Use a Cat5e or better cable and terminate to RJ45 connectors following the TIA EIA 568B wiring standard Connect Ethernet Cables to a Fixture The following instructions are guidelines for connecting Ethernet to your fixture Your installation may vary 1 Connect a cable from the Ethernet contr...

Страница 18: ...ed into the DMX output receptacle of the last fixture in the DMX control run This plug is available and sold separately Contact your authorized dealer or ETC for ordering information etcconnect com contactETC Set the DMX Start Address Give each fixture a unique DMX starting address so that the correct fixture responds to the control signals This DMX start address is the channel number from which t...

Страница 19: ... Browse the menu by pressing the up down left or right navigation buttons 3 Press the Enter button to select a menu item 4 Modify the selection by pressing the up down left or right navigation buttons according to the selection 5 Press the Enter button to confirm a modified selection 6 To exit the menu press the MODE ESC button Note If you press the Enter button to confirm a selection and push no ...

Страница 20: ... XXXX Hours Total running time of the device shown in hours h Last Run Hrs XXXX Hours Running time of the fixture from the last time that the run time value was reset shown in hours h LED Hours XXXX Hours Total running time of the fixture LEDs shown in hours h Timer PIN Timer PIN XXX You must enter the Timer PIN in order to access the Clr Last Run menu item The default Timer PIN is 038 Clr Last Ru...

Страница 21: ...e that displays on the main window of the UI until you select a different DMX value to view View Fixture Head Temperature Navigate Main Menu Info Head Temp Displays the current fixture temperature as read from the fixture head near the CMY filter View Fan Speeds Navigate Main Menu Info Fan Speed Displays the speeds of the fixture s fans in RPM View Ethernet IP Address Navigate Main Menu Info Ether...

Страница 22: ...ue is 1 Use this parameter to make fine adjustments to pan and tilt movement in order to correct for mis stepping when the fixture is installed on its side side hung or Outrig Hibernation OFF 1 99 minutes Hibernation mode forces the LEDs and stepper motors to power off when the fixture loses DMX control signal for a set period of time The default time setting is 15 minutes Defogger Defog OnOP Defo...

Страница 23: ...hat consists of the manufacturer ID and serial number Modifying this setting can break the RDM capability of this fixture Duplicate RDM UIDs on the same DMX control run will result in a data collision causing a communication failure Ensure that all fixtures have a unique RDM UID if RDM functionality is to be used If DMX splitters are used and RDM control is to be used these splitters must support ...

Страница 24: ...es Flip Display ON OFF Flip the display 180 when the fixture is mounted vertically The default value is OFF Shortcut With the main UI window displayed press to flip the display 180 Press to flip it back to its original orientation Key Lock ON OFF Lock the user interface The default value is OFF To unlock the user interface buttons press and hold the MODE ESC button for three seconds Set the Temper...

Страница 25: ...effects are canceled the shutter opens and the dimmer intensity is set to 100 Re Calibrate an Individual Feature Navigate Main Menu Test Calibration Please contact Technical Services before using this parameter See Help from Technical Services on page 2 You must enter the Calibration PIN in order to access the Calibration menu items The default Calibration PIN is 050 Once you have accessed the Cal...

Страница 26: ...fixture head s magnetic indexing circuit malfunctions optical or magnetic sensor failure the stepper motor is defective or the related IC driver on the main PCB has failed the CMY wheel is not located in the default position after the reset CTO Color This message displays after the reset of the fixture if any of the following conditions exist the fixture head s magnetic indexing circuit malfunctio...

Страница 27: ...y of the following conditions exist the yoke s magnetic indexing circuit malfunctions optical or magnetic sensor failure the stepper motor is defective or the related IC driver on the main PCB has failed the Pan movement is not located in the default position after the reset Tilt movement This message displays after the reset of the fixture if any of the following conditions exist the fixture head...

Страница 28: ...oth to avoid loss of output due to accumulation of dust dirt on the lens Never use alcohol or solvents 2 Clean the fans regularly to ensure maximum airflow and efficient cooling This will ensure that the light source operates in the best possible condition Note If you use compressed air to clean the fans hold the fan blades in place while cleaning them Letting the fans spin while using compressed ...

Страница 29: ...ceived including interference that may cause undesired operation Note This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radi...

Страница 30: ...and indoor EN 62471 2008 Photobiological safety of lamps and lamp systems EN 61347 1 2015 Lamp controlgear General and safety requirements EN 61347 2 13 2014 Lamp controlgear Par cular requirements for d c or a c supplied electronic controlgear for LED modules Electromagne c Compa bility Direc ve EMCD 2014 30 EU EN 55015 2013 A1 2015 Limits and methods of measurement of radio disturbance character...

Страница 31: ... c or a c supplied electronic controlgear for LED modules Electromagne c Compa bility Direc ve EMCD 2014 30 EU EN 55015 2013 A1 2015 Limits and methods of measurement of radio disturbance characteris cs of electrical ligh ng and similar equipment EN 61547 2009 Equipment for general ligh ng purposes EMC immunity requirements EN 61000 3 2 2014 Electromagne c compa bility EMC Limits Limits for harmon...

Страница 32: ...NY Orlando FL Los Angeles CA Austin TX Web etcconnect com Support support etcconnect com Contact etcconnect com contactETC 2021 Electronic Theatre Controls Inc Trademark and patent info etcconnect com ip Product information and specifications subject to change ETC intends this document to be provided in its entirety 2560M1200 1 2 11 Rev A Released 2021 06 ...

Отзывы: