ETC Setup Guide

Response SMPTE Gateway Setup Guide

Response SMPTE Gateway

Page 2 of 5

ETC

Unbalanced Audio

For an unbalanced input source, such as a 3.5 mm 
audio TRS jack from a mobile device or PC, make the 
following connections in the user cable: Connect XLR 
pin 1 and 3 together (tying Common to Signal -). The 
unbalanced signal connects to XLR pin 2 (). The 
3.5 mm audio TRS to XLR Male cable that is provided 
with the gateway is wired for unbalanced audio.

SMPTE Timecode

The gateway supports input of the following timecode formats:

Power and Connections

The SMPTE Gateway can use Power over Ethernet (PoE) or can be powered by USB. The following 
connection methods are available:

• Ethernet only: Ethernet is used to supply power (PoE) and to transport timecode over the network
• USB and Ethernet: Ethernet sends SMPTE timecode over the network and USB is used only for power
• USB only: The gateway is powered by and sends converted timecode over the USB connection. In this 

scenario, the USB connection must be made directly to the lighting console.

Switching the Network Port (Rack Mount Only)

The rack mount variant of the SMPTE gateway can have the Ethernet connector installed on the front or 
back of the unit. To switch the location, perform the following steps:

1:

Using a Phillips screwdriver, remove the four screws on the 
bottom of the gateway and slide the cover off from front to 
back.

2:

Using a Phillips screwdriver, remove the two screws from the 
nuts securing the blank plate to the gateway.

3:

Remove the two screws securing the Ethernet connector to 
the gateway.

4:

Move the Ethernet connector to the desired location on the 
gateway and secure with the two screws removed in step 3.

5:

Secure the blank plate to the other location using the screws 
and nuts removed in step 2.

6:

Slide the cover back on the gateway, from back to front and 
secure with the four screws you removed in step 1.

Note:

The TRS to XLR cable is provided only with the backpack version of the SMPTE gateway.

Rate

Drop Frame

Received As

23.98

Yes

24 Drop

24

No

24

25

No

25

29.97

No

30

29.97

Yes

30 Drop

30

No

30

R

L

Hot

Ground

1

2

3

Screws for cover removal

Содержание Response SMPTE

Страница 1: ...ion of the SMPTE gateway LED Indicators Power solid blue indicates that power is supplied Network solid green indicates network connection and blinking indicates network activity USB solid green indicates USB connection and solid red indicates connection without having fully detected identified and loaded device drivers Action Buttons Up Down Back buttons The Back button allows you to return to th...

Страница 2: ...n this scenario the USB connection must be made directly to the lighting console Switching the Network Port Rack Mount Only The rack mount variant of the SMPTE gateway can have the Ethernet connector installed on the front or back of the unit To switch the location perform the following steps 1 Using a Phillips screwdriver remove the four screws on the bottom of the gateway and slide the cover off...

Страница 3: ...ings is set to the same ID as the Source ID entered in your Event List Using SMPTE in Eos Event Lists You can trigger events in Eos from SMPTE using Show Control Event Lists For additional information on event lists in Eos refer to the Eos Family Operations Manual 1 On your console navigate to the Show Control tab and create a list 2 In the Type field enter SMPTE 3 In the Source field For SMPTE ov...

Страница 4: ...nual you must configure the IP Address IP Subnet and IP Gateway screens and then select OK from the Apply Reboot screen If you select Link Local you can have the addressing done using your system s link local addressing mechanism Select OK from the Apply Reboot screen If your network settings are not valid after configuration a warning appears for 3 seconds and then you are returned to the Mode sc...

Страница 5: ...gateways for mounting into a standard 19 rack enclosure If you only need to mount one unit a blanking plate is provided with the kit This blanking plate can be installed on either side of the rack mount bracket Hanging Hardware Kit 4260K1005 The Hanging Hardware Kit allows pipe mounting of a gateway in a variety of orientations You can vary the way the U bolt or c clamp attaches to the bracket and...

Отзывы: