ETC

Configure Port Settings

1.

From the Home screen, select Setup > Ports.

2.

Use the Enter button to move from the menu options on the left to the values on the right side
of the screen. Use the Up and Down buttons to change the values and press Enter again to
confirm the change. Using these controls, configure the fields on screen:

Port - Select the port for which the following values apply:

Mode - Select the port mode. This can be set to Input, Output or Disabled.

Universe - Select the Universe of the port (1-63999).

Speed - Select the speed at which DMX is transmitted. This can be set to Slow, Medium, Fast,
and Max.

Note:

For detailed DMX speed timings, visit:

https://support.etcconnect.com/ETC/FAQ/DMX_Speed

.

Configure RDM Settings

1.

From the Home screen, select Setup > RDM.

2.

Use the Enter button to move from the menu options on the left to the values on the right side
of the screen. Use the Up and Down buttons to change the values and press Enter again to
confirm the change. Using these controls, configure the fields on screen:

Port - Select the port for which the following values apply:

RDM - Select whether RDM is enabled or disabled on the port.

Background - Select whether background discovery and polling of RDM is on or off.

Configure Data Loss Settings

1.

From the Home screen, select Setup > Data Loss.

2.

Use the Enter button to move from the menu options on the left to the values on the right side
of the screen. Use the Up and Down buttons to change the values and press Enter again to
confirm the change. Using these controls, configure the fields on screen:

Port - Select the port for which the following values apply:

HLLF - Select whether Hold Last Look Forever (HLLF) is on or off. Selecting On enables Hold
Last Look Forever. Additional configuration options for hold last look are available in Concert.

Содержание Response Mk2 One-Port

Страница 1: ...re information ETC Concert software can be found at etcconnect com Concert Overview There are two versions of the Two Port Gateway a wall mount version and a portable version Wall mount Front View Wall mount Back View OLED screen Touch to Wake Sensor Up Down Back Enter buttons Reset button Available connectors DMX Out XLR Female DMX In XLR Male DMS RJ45 Aux power Ground screw Ethernet Action Butto...

Страница 2: ...ons There are three different connector types available depending on your gateway DMX Out five pin female XLR DMX In five pin male XLR DMX RJ45 input or output The Response Mk2 Gateways send and receive DMX 512 control signals DMX cables must be acceptable for DMX data transmission and connections should follow the standard pinouts per the charts below The optional secondary data pair is not used ...

Страница 3: ...t RDM Remote Device Management RDM ANSI E1 20 is a protocol enhancement to DMX 512 that allows bidirectional communication between a lighting system controller and attached RDM compliant responder devices over a standard DMX line This protocol allows configuration status monitoring and management of these devices An RDM Controller is the device that initiates communication with one or more RDM Res...

Страница 4: ...tach the bezel as the wires must pass through the bezel from the back box Using the four screws provided secure the bezel to the back box Connect Wiring Aux power Ethernet Ground screw Pull all required wiring to the back box including an Ethernet cable Category 5e or better and ground wire Terminate the Ethernet cable using the included kit part 4101A2003 Then connect the termination box to the g...

Страница 5: ...ugh plate Secure bottom magnets Press in top and secure face plate 5 Shift the plate down until the bottom magnets secure the plate to the gateway and then press in the top so the entire face plate is secure Ethernet DC power input Ground point Mounting bracket Portable The portable version of the gateway is designed for easy setup and can be mounted using the mounting bracket The bracket contains...

Страница 6: ...universe 100 Additionally DD indicates a dimmer doubled port AIP indicates Advanced Input Patch indicates a port in downloader mode and X indicates a disabled port Pressing the Enter button from the Home screen brings up three selectable menu options About Setup Operations from which you can access other information or configuration options If you receive a User Interface Locked message when acces...

Страница 7: ...e the Enter button to move from the menu options on the left to the values on the right side of the screen Use the Up and Down buttons to change the values and press Enter again to confirm the change Using these controls configure the fields on screen Port Select the port for which the following values apply RDM Select whether RDM is enabled or disabled on the port Background Select whether backgr...

Страница 8: ...e it in the Concert application using the Update Server property Note Regardless of whether you update from UpdaterAtor or directly from the gateway the device must be on the network Test Port Output You can test DMX outputs by selecting Operations Test Output from the Home screen CAUTION Testing outputs drives all DMX levels to full Use with caution in a show situation or when controlling high cu...

Отзывы: