ETC Installation Guide
Relevé Spot
Relevé Spot
Page 2 of 8
ETC
Power Requirements
Input Power Voltage Range
•
100-240 VAC at 50/60 Hz
-
Relevé Spot features a universal auto-switching power supply
Power Factor
•
Maximum power consumption - 285 W
•
Minimum power consumption - 29 W
Luminaires per Circuit (20 A)
•
4 luminaires at 100 VAC
•
5 luminaires at 120 VAC
•
10 luminaires at 240 VAC
•
Note:
Relevé Spot requires power from a non-dimmable source. Consult the upstream
breaker trip curve specification for compatibility information with the required input power.
Environment
•
The Relevé Spot luminaire operates in ambient temperatures of 0-40°C (32-104°F), and
relative humidity range 5-95%, non condensing
•
The Relevé Spot is IP20, rated for indoor use only
-
IP2x indicates protected against intrusion by fingers or similar objects
-
IPx0 indicates no protection against liquid contact and ingress of liquid objects
Attach Clamp Mounting Rails
CAUTION:
Risk of Personal Injury! Overhead mounting requires extensive
experience, including amongst others, calculating the working load limit (WLL) of
the truss system, a specialized knowledge of the installation material being used,
and a periodic safety inspection of all installation materials and the luminaire.
Improper installation can result in bodily injury. This luminaire must be installed
by qualified personnel only.
ATTENTION :
Risque de Blessures Corporelles ! L’installation en hauteur
nécessite une vaste expérience, qui inclut notamment le calcul de la charge
nominale du système de pont, une connaissance spécialisée du matériel utilisé
pour l’installation et l’inspection régulière de tout l’équipement de l’installation
et du luminaire. Une installation incorrecte peut entraîner des blessures
corporelles. Ce luminaire doit uniquement être installé par du personnel qualifié.