INDUSTRIAL INSTRUMENTATION
Страница 1: ...INDUSTRIAL INSTRUMENTATION...
Страница 2: ...n screen 3 Wiring connection for Flex CK model Flex 4 Wiring connection for Flex CK model Flex 2100 5 Selection Menu 6 First use of the indicator 7 Calibration 8 Setup the Checkweigher configuration 9...
Страница 3: ...dicator stable Create new Tare level Create new zero level Return to main menu Speed bar maximum Actual production speed Select edit recipe Start controller in run mode Sign Actual High level Actual L...
Страница 4: ...ex Output Reject Low Output Reject High Output Check Busy Output Check OK Digital Outputs Digital Inputs Input 1 Start option Input 2 Stop option Input 3 Start Check Input 4 8 Not used AC Power supply...
Страница 5: ...nnection for Flex CK model Flex 2100 Digital Inputs Loadcell connection Digital Outputs Input 1 Start option Input 2 Stop option Input 3 Start Check Input 4 8 Not used Output Check OK Output Reject Lo...
Страница 6: ...e to enter the several Screens The Configuration and System setting are locked by a password log in with the Log in button first To log out press the Log out button The overall password is 25630 Scree...
Страница 7: ...10 20 50 100 200 500 1000 2000 or 5000 The Decimal point defines the point position of the weight value Decimal point position can be set from NONE to 0 00000 All previous calibration points should fi...
Страница 8: ...press OK This CAL code is shown in the right upper corner Delete all old calibration points Make sure all points are deleted Make sure the weigher is empty and press the Activate button to save the ze...
Страница 9: ...ngs Default no password is selected The overall password is 25630 Press the blue Edit fields to enter the needed values Press the question marks to open information about the parameter Press the OK bu...
Страница 10: ...September 1 2011 WEIGHT CONTROLLER TYPE FLEX CHECK CATCH WEIGHER ETC Configuration Parameters 10 Configuration Parameters...
Страница 11: ...recipe name in the blue fields Use the scroll bar to select the next recipes The screen will automatically return to the production screen after selection To edit a recipe Press the recipe number in...
Страница 12: ...me button To edit a recipe parameter press the value in the blue fields Press the question marks to open information about the parameter To return to the previous screen and save the recipe press the...
Страница 13: ...September 1 2011 WEIGHT CONTROLLER TYPE FLEX CHECK CATCH WEIGHER ETC Recipe parameters 13 Recipe parameters...
Страница 14: ...ress the production data button To reset the subtotals press the Subt Button To reset the totals and subtotals press the Total button Press the Question marks to open information about the parameter T...
Страница 15: ...September 1 2011 WEIGHT CONTROLLER TYPE FLEX CHECK CATCH WEIGHER ETC Information 15 Information To view the Penko contact information press the information button from the selection menu...
Страница 16: ...ut 3 4 Check busy ON 5 Wait for stable and Holdtime parameter 6 Take amount of Samples 7 Check if weight is too low a No to point 8 b yes start Delay time low 8 Check if weight is too High a No to poi...