Power
11
Power
Input and Power Factor
VAC
Amps
Hz
Watts
VA
PF
100
19.4
50
1891
1938
0.99
120
15.2
60
1815
1822
0.99
200
8.6
50
1710
1723
0.99
208
8.3
60
1716
1730
0.99
220
7.8
50
1704
1721
0.98
240
7.2
60
1704
1726
0.98
CAUTION:
Using this fixture below 100 V on a 15 A breaker may cause the
breaker to trip. Ensure that the circuit can handle the fixture's maximum
potential draw before you connect it.
Connector Specification
WARNING:
Risk of Shock and Fire. Assemble a grounding-type attachment
plug with integral cord grip that is within the voltage and amperage rating
of this luminaire.
AVERTISSEMENT :
Risque de choc et d'incendie. Assurez-vous d'utiliser
une prise de mise à la terre avec décharge de traction intégrée qui respecte
la tension et l'ampérage de ce luminaire.
A power input cable with powerCON
®
TRUE1
®
TOP input to bare ends is provided. The power
input cable is rated for maximum 20 A/120 VAC and 16 A/240 VAC. Install a suitable connector
to meet the installation requirements. See the following wire color code chart:
Wire Color Code (EU) Wire Color Code (US Standard) Connection type Terminal
Green/Yellow
Green
Earth/Ground
Blue
White
Neutral
N
Brown
Black
Line (Live)
L