background image

ETC Installation Guide

ColorSource Linear v1.7

Corpora te He a dqua rte rs Middleton, WI, USA +1 608 831 4116
London, UK +44 (0)20 8896 1000 Holzk irc he n, DE +49 (80 24) 47 00-0
Rome , IT +39 (06) 32 111 683 Hong Kong +852 2799 1220 P a ris, FR +33 1 4243 3535
We b

etcconnect.com

Support

support.etcconnect.com

Conta c t

etcconnect.com/contactETC

© 2020 Electronic Theatre Controls, Inc.

Product information and specifications subject to change. ETC intends this document
to be provided in its entirety. Trademark and patent info: 

etcconnect.com/ip

7 4 1 4 M 2 1 0 0 -1 .7 Rev C Released 2020-03

Overview

The ColorSource Linear is an affordable LED fixture that uses the RGB-L (red,
green, blue, and lime) color system to provide a rich, bright light.

The fixture is available in three lengths:

ColorSource Linear 1 (0.5 meter)

ColorSource Linear 2 (1 meter)

ColorSource Linear 4 (2 meter)

The ColorSource Linear is available in both original and Deep Blue variants.
The Deep Blue uses an array that offers richer, more saturated blues and
stronger magentas in exchange for the more jewel-toned blues like sky or
turquoise. For more information, see the ETC website at

etcconnect.com

.

Note:

Features described in this document require the latest version

of software. For information on updating fixture software, see

Update

the Fixture Software on page 14

.

Содержание ColorSource Linear

Страница 1: ...020 03 Overview The ColorSource Linear is an affordable LED fixture that uses the RGB L red green blue and lime color system to provide a rich bright light The fixture is available in three lengths Co...

Страница 2: ...ing the following READ AND FOLLOW ALL SAFETY INSTRUCTIONS Do not use outdoors Do not let power supply cords touch hot surfaces Do not mount near gas or electric heaters Equipment should be mounted in...

Страница 3: ...7 F External Temperature steady state achieved at 25 C 77 F 48 C 118 F Electrical Operates between 100 V and 240 VAC at a frequency of 50 60 Hz Maximum power consumption Linear 1 120 W Linear 2 240 W...

Страница 4: ...everal half meter optional accessories with ColorSource Linearfixtures including Secondary lenses horizontal vertical and round Barn doors 7414K1020 Louver 7414K1019 For information on installing seco...

Страница 5: ...able anchor point Cutout for cable strain relief Safety Cable Two safety cable anchor points are provided on the fixture housing The anchor points also include two cutouts that can be used for cable s...

Страница 6: ...on the following page for reference 1 Plug the power cord into the powerCON In connector on the rear of the fixture 2 Make any power thru cable connections prior to applying a power source 3 Make any...

Страница 7: ...n press the Mode button to access the Presets Sequences menu See Play Presets and Sequences on page 12 Adjust the Tilt The fixture can be tilted up and down as needed 1 Loosen but do not remove the tw...

Страница 8: ...button to change the DMX control mode 5ch 5 channel mode intensity red green blue and strobe This is the default mode dir Direct emitter control intensity red green blue indigo lime and strobe 1ch 1 c...

Страница 9: ...X control mode see Change the DMX Control Mode on the previous page For example if you set the DMX address on the fixture to 100 set the DMX mode to 5 channel and set the Grouping mode to Cell the sta...

Страница 10: ...Blue 4 Blue Blue Indigo Cell 2 Red 5 Strobe Lime Green 6 Cell 2 Intensity Strobe Blue 7 Red Cell 2 Intensity 8 Green Red 9 Blue Green 10 Strobe Blue Indigo 11 Lime 12 Strobe Original ColorSource Linea...

Страница 11: ...3 Red 8 Green Red Green 9 Blue Green Blue 10 Strobe Blue Indigo Cell 4 Red 11 Cell 3 Intensity Lime Green 12 Red Strobe Blue 13 Green Cell 3 Intensity 14 Blue Red 15 Strobe Green 16 Cell 4 Intensity...

Страница 12: ...ixture See Re record Presets on the facing page When a Linear 2 or Linear 4 fixture is in Cell mode you can re record a preset with each cell having a distinct set of values See Set the Grouping Mode...

Страница 13: ...esets When you re record presets with the fixture in RGB mode rgb the intensity is set to full and the strobe is turned off See Change the DMX Control Mode on page 8 Adjust the Intensity of Presets 1...

Страница 14: ...newer software version or update a ColorSource fixture to a newer software version using UpdaterAtor you can use that fixture to push the newer software version to all connected ColorSource fixtures e...

Страница 15: ...ry lenses are included with the fixture Use these spacers to hold the accessories in position when multiple lenses are used in the Linear 2 and Linear 4 fixtures 1 Loosen the thumbscrew on the access...

Страница 16: ...unplugged Verify that internal cables are properly connected If the error persists the fixture will need to be returned to the ETC factory contact your local dealer to set up a repair No App Screen to...

Страница 17: ...inear 4 Deep Blue 0x0212 DMX Start Address All 0x00F0 Range 1 512 DMX Personality Linear 1 0x00E0 1 5 Channel 2 Direct 3 1 Channel 4 RGB Linear 2 in Group mode Linear 4 in Group mode Linear 2 in Cell...

Страница 18: ...ETC Installation Guide ColorSource Linear v1 7 ColorSource Linear Page 18 of 20 ETC...

Страница 19: ...ETC Installation Guide ColorSource Linear v1 7 ColorSource Linear Page 19 of 20 ETC...

Страница 20: ...cate a problem with the color calibration The fixture will need to be returned to the ETC factory contact your local dealer to set up a repair OtP Screen toggles between OtP and ERR to indicate that t...

Отзывы: