14
CEM3 User Manual
About
Field
Description
Dimmers
View all properties for any circuit in a space or in any rack on the network.
See
Rack
View all properties for the host Sensor rack. See
• Status: displays "Rack OK" or "Errors Exist"
• Panic State: displays "Ready" when not in a panic condition and
"Active" when in a panic condition.
Errors
View any current errors or other status messages. See
Source Info
View the current control source (Highest-Takes-Precedence or “HTP”) and
related output level being received by all dimmers in a space.
• "DMXA" is DMX Port A
• "DMXB" is DMX Port B
• "sACN" is Streaming sACN
• "AF" means Advanced Features is using the dimmer for load
recording
• "SetLevels" means Set Levels or Dimmer Check is in use on
the dimmer
• "ACNDirect" is ACN Direct Control
• "Preset" followed by a number means a preset is running on
the dimmer
• "Panic" means the panic settings are in effect
• "--" means no control of the dimmer
About CEM3
Displays the current software version on your CEM3 processor. You can
also save a copy of the
CEM3 User Guide
to a USB drive.