ETC Installation Guide
Pro One-Cell
Pro One-Cell
Page 15 of 29
ETC
Luminaire Connection to Driver
ArcSystem Pro One-Cell luminaires connect to a driver using Molex receptacles labeled "LED Head"
for D1 and D2 Series Drivers and "LED" followed by output channel number for D4 Series drivers. All
D1 Series and D2 Series drivers and some models of D4 Series drivers have Molex receptacles for
ArcSystem Pro One-Cell luminaire connections. Models of D4 Series drivers with two-pin terminal
outputs can be used to provide power and data to other fixtures.
Note:
Maximum supported wire length between One-Cell luminaires and D1 Series and
D2 Series drivers is 15 m (49 ft).
Maximum supported wire length between any load and a D4 Series driver is 10 m (33 ft).
1.
Install the ceiling with the prepared mounting hole for the luminaire.
2.
Run the luminaire cable through the previously installed screw-clamp conduit connector at one
of the driver knockouts.
Two-pin terminal wiring
Line
Neutral
Line
Neutral
Line
Neutral
Line
Neutral
3.
Connect the luminaire cable to the driver output.
•
D1 Series, D2 Series, and D4 Series Drivers
with Molex receptacles: connect the four-pin
luminaire cable(s) to the Molex receptacle(s)
inside the driver. See
. Support the luminaire(s).
Do not let luminaires hang by their cables.
•
D4 Drivers with terminal outputs: wire loads
(luminaires) to a provided two-pin connector
and insert the connector into a two-pin
terminal inside the driver. See the illustration at
right.
-
Constant Current (CC) drivers: verify that
each output channel's current output is
configured correctly. See