D4 Series Drivers Installation Guide
D4 Emergency Driver 150 Current Configuration
See
D4 Driver 150 Current Configuration on page 26
for information on configuring the driver
current in a standard constant current D4 Driver 150.
Note:
Do not change the switch settings on a D4 Constant Voltage (CV) model driver.
Constant Current (CC) D4 Driver 150 models can be configured for 400 mA or 600 mA output
using the four switch blocks shown in the illustration of the
Wall-Mount Driver Wiring Overview
.
Outputs
Each of the four switch blocks controls one output.
•
Switch block S1 controls LED1.
•
Switch block S2 controls LED2.
•
Switch block S3 controls LED3.
•
Switch block S4 controls LED4.
Switch Functions
Each switch block has six switches.
Note:
Do not change the switch 1 settings on a D4 Constant Voltage (CV) model
driver.
•
Switch 1 sets the current output threshold.
ON = 400 mA, OFF = 600 mA.
•
Switches 2 through 5 control the DMX channel assigned to the output.
•
Switch 6 enables emergency functionality.
Switches 2 through 5 are factory set to allow each output to be controlled by an individual
DMX address. ETC recommends leaving the DMX channel switches (positions 2 through 5) at
their factory settings and using the ArcSystem Configuration Software or RDM settings to control
the behavior of each output.
Note:
ArcSystem D4 Drivers are factory configured for 600 mA output for
compatibility with ArcSystem Pro One-Cell and One-Cell Small luminaires. If you power
a One-Cell or One-Cell Small luminaire from a D4 output channel that is configured for
400 mA, the output of the luminaire may be dim.