Rack-Mount Driver Installation
29
RJ45 Pin
Description
1
data +
2
data -
7 & 8
ground
DMX In and DMX Thru
DMX In and DMX Thru cables terminate to RJ45 connectors.
DMX is installed in a daisy chain topology and includes one
pair of wires (data +, data -) plus an ISO ground (common).
Terminate DMX In and Thru
ETC recommends Cat5e (or better) minimum 0.2 mm
2
(24 AWG) conductors terminated to
T568B standard.
Note:
ArcLamp drivers are not self-terminating. You must terminate the last driver in
line with a DMX terminator plug in the RJ45 Thru receptacle. To purchase an RJ45
terminator, please contact your ETC customer service representative and request part
number N4086.