4.4

Power Supply 

The XETK-S4.2 requires a permanent power supply. It is typically powered 
directly from the car battery. The input voltage may vary between 4.3 V and 
36 V. In case of higher input voltages to the XETK, additional voltage protection
is required. The XETK-S4.2 will also accept voltage dips down to 3V, for a maxi-
mum duration of 15ms (for additional details of low voltage operation, see ISO

 

standard 16750)
From the input battery voltage, the XETK-S4.2 creates all necessary voltages 
through switching power supplies on the XETK-S4.2. The power supply of the 
ECU is not affected by the XETK-S4.2. An automatic switch ensures that the 
power supply of the XETK-S4.2 is automatically switched on and off when the 
XETK enters and leaves its standby (sleep) mode.
The XETK-S4.2 can be supplied with power through the seven pin connector, 
CON7. The through-hole solder pad CON4 can be used additionally to connect a 
power supply U

Batt2

The power supply on CON4 must use the GND of CON7 pin 3.  

Fig. 4-4

Location of the XETK-S4.2 Power Supply Connectors

CON7

CON4

Содержание XETK-S4.2

Страница 1: ...XETK S4 2 Emulator Probe for Infineon AUDO MAX MCU Family User s Guide...

Страница 2: ...single license Using and copying is only allowed in concurrence with the specifications stipulated in the contract Under no circumstances may any part of this document be copied reproduced transmitted...

Страница 3: ...ies for Operators 8 2 3 Intended Use 8 2 4 Identifications on the Product 11 2 5 Taking the Product Back and Recycling 12 2 6 CE marking 12 2 7 RoHS Conformity 12 2 7 1 European Union 12 2 7 2 China 1...

Страница 4: ...S4 2 Microcontroller Support 33 7 2 1 Data Emulation Memory and Microcontroller Support 33 7 2 2 Measurement Data Memory 33 7 3 Configuration 33 7 4 XETK Ethernet Interface 34 7 5 Environmental Condi...

Страница 5: ...8 4 1 Cable K70 48 8 4 2 Cable KA50 49 8 5 ECU Interface Adapters 50 8 5 1 XETK ECU Adapter ETAI4 50 8 5 2 XETK ECU Adapter ETAI8 50 9 Ordering Information 51 9 1 XETK S4 2 51 9 2 XETK ECU Adapter 51...

Страница 6: ...Information All activities to be performed by the user are presented in a Use Case format That is the goal to be accomplished is briefly defined in the heading and the respective steps required for re...

Страница 7: ...ivered with all required components and cables see chapter Order ing Information Additional cables and adapters can be obtained separately from ETAS A list of accessories and their order designation i...

Страница 8: ...The product may be assembled operated and maintained only if you have the necessary qualification and experience for this product Incorrect operation or operation by users without sufficient qualific...

Страница 9: ...e product by disconnecting it from the power supply or by switching off the power supply Potential Equalization Requirements for the technical State of the Product The product is designed in accordanc...

Страница 10: ...out cabling is located in the ETK User s Guides CAUTION The ETK can be damaged or destroyed Some components of the ETK board may be damaged or destroyed by electrostatic discharges Please keep the ETK...

Страница 11: ...12 Symbol for CE conformity see chapter 2 6 on page 12 Symbol for China RoHS see chapter 2 7 2 on page 12 Symbol for China RoHS see chapter 2 7 2 on page 12 Symbol for electrostatic sensitive componen...

Страница 12: ...to the product or its packaging ETAS confirms that the product corresponds to the applicable product specific European Directives The CE Declaration of Conformity for the product is available upon req...

Страница 13: ...ad center in the customer information REACH Declaration www etas com Reach This information is continuously being updated 2 9 Use of Open Source Software The product uses Open Source Software OSS This...

Страница 14: ...the PC No additional ETAS modules are required for the access to the ECU The XETK S4 2 can be used for rapid prototyping applications bypass as well as for measure ment and calibration applications 3...

Страница 15: ...on Ethernet Protocol Supports a variety of standard applications Firmware update programming of the logic device through software removal of XETK or ECU is not necessary Mounting possibilities inside...

Страница 16: ...rameters characteristic lines and maps through the calibration and development system Using an additional measure ment data memory area the ECU microcontroller can provide data to the calibra tion and...

Страница 17: ...which is not used for XETK power supply but only for detection of the ECU status therefore the power consumption on this line is negligible refer to chapter 4 4 on page 19 1 Reset line which allows t...

Страница 18: ...ent and Calibration standard XCP on Ethernet TCP IP UDP IP The open XCP on Ethernet interface allows for connecting to the XETK S4 2 with third party application software Fig 4 3 Location of the XETK...

Страница 19: ...tandard 16750 From the input battery voltage the XETK S4 2 creates all necessary voltages through switching power supplies on the XETK S4 2 The power supply of the ECU is not affected by the XETK S4 2...

Страница 20: ...wo signals are only used for monitoring therefore the load current is negligible The XETK S4 2 supplies the ECU EDRAM using the pin VDDSBRAM and monitors this voltage using a sense pin on board the XE...

Страница 21: ...i bration and development system has downloaded data since the last power failure Switching between the Refer ence Page and Working Page is possible On Power supply has dropped under selected threshol...

Страница 22: ...ference Page to the Working Page and vice versa is known as page switching The XETK S4 2 supports Protocol Based page switching for all supported micro controllers Switching between Reference and Work...

Страница 23: ...l termination resistors are required on the ECU debugger PCB for these signals It is mandatory for the ECU to provide impedance matched series termination resistors of 22 Ohms for the signals TDO and...

Страница 24: ...ATE register to ensure the XETK S4 2 has completed the IO_SET_OJ CONF operation Application running The ECU software detects the connected XETK by reading CBS_OSTATE register Thereafter the ECU softwa...

Страница 25: ...d is used for triggering The time intervals between trigger events are in accordance with the configured timer values This values and their resolution have to be defined in the A2L file Available sett...

Страница 26: ...nnector details should have been populated onto the ECU PCB for adapters ETAI4 and ETAI8 Fig 5 1 XETK S4 2 Connection to the ECU CAUTION Some components of the interface board may be damaged or destro...

Страница 27: ...Interface Fig 5 3 Wiring XETK Ethernet Interface PC E S910 PC C B E200 3 C BAE 200 2 1 m20 C BAE 330 2 0 m5 Lem o 10 f Lem o 10 f Lem o 10 f R J45 Lem o 8 m Lem o 10 m R J45 ES 51 x ES51 x C B E230 1...

Страница 28: ...g 5 5 Permanent Power Supply inside ECU not available Isolated Power Supply inside ECU The XETK S4 2 does not require a galvanically isolated power supply For special applications ETAS offers the isol...

Страница 29: ...n Fig 5 6 Isolated Power Supply inside ECU ECU 12V Permanent Supply ECU Connector 4 8V 36V Input Output 12 V ETK Pad for Power Supply ca 36 V Power Supply Connector Vehicle Battery Vehicle Wiring Cabl...

Страница 30: ...rformed 2 Connection of the ETK to the ECU The ECU hardware developer defines the connection of the ETK to the ECU The corresponding signals usually have to be adjusted for each microcontroller All in...

Страница 31: ...in window of the XCT tool opens Select in the menu bar Contents The X ETK Configuration Tool help window opens Choose Reference to User Interface X ETK Hardware Configuration Parameters Choose the top...

Страница 32: ...n in the Power Management register Confirm your configuration The manufacturers of network adapter have different names for this function Example Link down Power saving Allow the computer to turn off...

Страница 33: ...and states if the ED RAM is capable of being powered using a standby supply 7 2 2 Measurement Data Memory 7 3 Configuration Microcontroller Max ED RAM Standby powered TC1728ED 384 kByte Yes TC1782ED 5...

Страница 34: ...IP or UDP IP IP address Dynamic standard for INCA or static e g for Rapid Prototyping by using the XETK Configuration Tool default IP address 192 168 40 16 Cable length max 30 m 100 ft Ethernet Interf...

Страница 35: ...20 C 240 300 mA Power dissipation PBatt UBatt 12 V I 0 mA at pin ECU_SBRAM T 20 C 1 62 W Power dissipation PBatt UBatt 12 V I 600 mA at pin ECU_SBRAM T 20 C 2 88 W 1 The XETK S4 2 implements reverse v...

Страница 36: ...ng the FPGA UBatt pres ent VDDP will be switched on 2 max delay of ECU reset through the XETK UBatt and VDDP will be switched on Parameter Symbol Condition Min Typ Max Unit Reset delay 1 1 tReset1 UBa...

Страница 37: ...TAG interface CON1 CON6 of the XETK S4 2 The JTAG wiring to the ECU ETAF1 ETAI1 must be taken account additionally All timings are measured at a reference level of 1 5 V Output signals are mea sured w...

Страница 38: ...wer Supply Supervision Voltage 5 0 V selected VDDP VDDP 2 98 3 08 3 18 V VDDP 2 83 2 93 3 03 V IVDDP VDDP 5 0 V 300 A ECU Standby RAM Supervision Voltage 0 74 V 0 97 V selected VDDSBRAM VDDSBRAM 0 74...

Страница 39: ...RAM VDDSBRAM 1 5 V 90 A ECU Standby RAM Supervision Voltage 1 29 V 1 51 V selected VDDSBRAM VDDSBRAM 1 29 1 39 1 49 V VDDSBRAM 1 31 1 41 1 51 V IVDDSBRAM VDDSBRAM 1 6 V 95 A ECU Standby RAM Supervisio...

Страница 40: ...selected VDDSBRAM VDDSBRAM 2 20 2 30 2 40 V VDDSBRAM 2 23 2 33 2 43 V IVDDSBRAM VDDSBRAM 2 5 V 145 A ECU Standby RAM Supervision Voltage 2 41 V 2 64 V selected VDDSBRAM VDDSBRAM 2 41 2 51 2 61 V VDDSB...

Страница 41: ...VDDSBRAM max 600 mA load 1 47 1 5 1 52 V 1 VDDP ECU Power Supply off ECU Power Supply on VDDP ECU Power Supply on ECU Power Supply off VDDSBRAM ECU Standby RAM Power off ECU Standby RAM Power on VDDSB...

Страница 42: ...8 2 5 5 44 12 PORST I 5 0 8 2 5 5 3 10 Reserved0 I 0 8 2 5 5 3 10 WDGDIS O 5 5 22 6 1 Adapter cable and Samtec connector not considered PCB 1 pF cm 2 max 3 min 4 Open Drain FET IDmax 500 A 5 Open Drai...

Страница 43: ...BRKOUT In Debugger break signal A4 TDI Out JTAG signal A5 TDO In JTAG signal A6 WDGDIS Out Watchdog disable signal B1 BRKIN Out Debugger break signal B2 GND Signal Ground B3 TMS Out JTAG signal B4 PO...

Страница 44: ...tandby RAM provided by the XETK optional additional sense 2 5 HDRST In ECU reset signal for reset detection 6 DAI1 opt SENSE Bidir GPIO pin for startup communication and trig gering optional additiona...

Страница 45: ...ons Side View Item Dimension Millimeters Tolerance Millimeters Dimension Inches Tolerance Inches A 60 00 0 20 2 362 0 008 B 56 50 0 20 2 224 0 008 C 3 50 0 10 0 138 0 004 D 3 25 0 10 0 128 0 004 E 37...

Страница 46: ...ous ing 8 1 2 CBAM240 1 Adapter Cable Fig 8 2 CBAM240 1 Adapter Cable XETK ECU Adapter Cable 100 MBit s shield connected to ECU housing lead through diameter for cable 10 mm 0 6 m length shield bare f...

Страница 47: ...200 2 Adapter Cable Fig 8 4 CBAE200 2 Adapter Cable Cable adapter to connect CBE230 cable to the PC over an RJ45 connector The CBAE200 2 1m20 supports Gigabit Ethernet Product Length Order Number CBE2...

Страница 48: ...dapter Cable Fig 8 6 CBAE330 2 Adapter Cable Gigabit to 100 MBit s Ethernet Adapter for connection of CBE230 to ES600 Cable adapter to connect CBE230 cable with the ES600 Power supply over the CBAE330...

Страница 49: ...XETK S4 2 User s Guide 49 ETAS Cables and Accessories 8 4 2 Cable KA50 Fig 8 8 Power Supply Cable KA50 Dim Millimeters Inches A 200 7 87 B 50 1 97 A B...

Страница 50: ...Fig 8 9 XETK ECU Adapter ETAI4 8 5 2 XETK ECU Adapter ETAI8 Fig 8 10 XETK ECU Adapter ETAI8 Dim Millimeters Inches A 100 00 3 94 Note See Fig 5 2 on page 27 for details on mating connector to the ETAI...

Страница 51: ...AUDO F AUDO NG or AUDO MAX microprocessor ECU adaptation via 12 pin Erni and 7 pin JST plug Order Name Short Name Order Number ETAI4 XETK ECU Adapter Erni 12 to Erni 12 Samtec 12fc 12fc 0m10 ETAI4 F00...

Страница 52: ...00K 105 791 XETK ECU Adapter cable 100 MBit s Lemo 1B HME JST PHE 10fc 5fc 0m6 CBAM240 1 0m6 F 00K 105 792 Order Name Short Name Order Number Ethernet PC Connection Cable 1GBit s Lemo 1B FGE RJ45 10mc...

Страница 53: ...Power Supply Cables Order Name Short Name Order Number External Power Supply Cable for XETKs Lemo 0B FGG open wires 2fc 1c 2 m K70 Y 261 A24 942 XETK Power Supply Cable for External Sup ply with Filte...

Страница 54: ...or details of your local sales office as well as your local technical support team and product hotlines take a look at the ETAS website Borsigstra e 24 Phone 49 711 3423 0 70469 Stuttgart Fax 49 711 3...

Страница 55: ...2C Connection to the ECU and to the Debugger 27 Fig 5 3 Wiring XETK Ethernet Interface 27 Fig 5 4 Permanent Power Supply inside ECU available 28 Fig 5 5 Permanent Power Supply inside ECU not availabl...

Страница 56: ...XETK S4 2 User s Guide 56 Figures ETAS...

Страница 57: ...onfiguration Parameter 30 D Data Emulation 22 Data Emulation Memory 33 Data Measurement 22 Documentation 8 E ECU Interface 17 ECU Interface Characteristics 38 ECU Voltage Supervisor 20 Electrical Char...

Страница 58: ...tion of information 6 Product Exclusion of liability 8 Product Back 12 R REACH regulation EU 13 Recycling 12 Reset 25 RoHS conformity China 12 European Union 12 S Safety notices Identification 6 Safet...

Отзывы: