To connect an ES593.1-D with ES59x measure modules
1. Connect the
ETH1
port of the ES593.1-D with the Ethernet
cable CBE130.
2. Connect the second cable connector with the
HOST
port of an
ES59x measure module.
3. Connect further modules in accordance with this principle with
the
ETH2
port of the ES593.1-D.
Complex Module Network
A complex module network consists of several cascaded ES59x line modules
with connected measure modules. ES59x measure modules are used in the
following example.
With larger module networks, it is a good idea to make a sketch of the planned
module network. The following figure shows an example of a module network
with three cascaded ES59x modules.
Fig.
6
-
5
Example of a Module Network
To connect an ES59x module with other ES59x modules
1. Connect the
HOST
port of the subordinate ES59x module with
the
ETH1
port or with the
ETH2
port of the superordinate
ES593.1-D module
or
1. connect the
HOST
port of the subordinate ES59x module with
the
ETH1
port of the superordinate ES595.1 module
The superordinate ES59x module is nearer the host PC in the
hierarchy.
2. Connect further ES59x modules in accordance with this princi
-
ple with other
ETH
ports of the ES59x module.
6.4
Configuring the ES593.1-D
The ES593.1-D is configured at the PC via a graphic user interface. A web
browser application is used as an interface.