ETAS
Getting Started
ES593.1-D
-
User Guide
30
6.3.1
“HOST” Port
To connect the ES593.1-D module with the PC (“HOST” port), you require the
CBE100 cable provided.
To connect the ES593.1-D with the PC
1. Connect the
HOST
port of the ES593.1-D with the PC interface
cable CBE100.
2. Connect the cable’s RJ-45 connector with the free Ethernet
interface of your PC.
6.3.2
“7-29V” Port
To connect the ES593.1-D module with the power supply, you require the
CBP120 cable or the CBP1205 cable provided.
To connect the ES593.1-D with the power supply
1. Connect the cable CBP120 or the cable CBP1205 for the power
supply with the
7-29V
port of the ES593.1-D.
2. Connect the supply voltage pins of the cable with the required
power supply.
Note the color coding of the connectors.
Note the current consumption of the ES593.1-D and its supply
voltage range. The admissible values are listed in section
8.10.1 on
47.
6.3.3
“ETH1” and “ETH2” Port
To connect the ES593.1-D module with other modules (“ETH1” and “ETH2”
port), you require the CBE130 cable.
Simple Module Network
A simple module network consists of a single ES593.1-D module with con
-
nected network or measure modules. ES59x measure modules are used in the
following example.
NOTE
Make sure you carefully check the names of the cables used. Using the wrong
cables can keep your ES593.1-D from functioning properly or damage
theES593.1-D and any devices connected to it.
DANGER
Dangerous electrical voltage!
Connect the power cable only with a suitable vehicle battery or with a suitable
lab power supply! The connection to power outlets is not allowed!
To prevent an inadvertent insertion in power outlets, ETAS recommends to
equip the power cables with safety banana plugs CBP1205 in areas with
power outlets.