ETAS
Hardware description
ES583.1 - User's Guide
13
3.4.1
Operating state of the module
At the top of the module is the LED ON/ER to display the operating and error
state of the module (see Fig. 3
• Operating state
• Error states or firmware update of the module
• Overtemperature inside the housing
Functional states of the module (LED "ON/ER")
The LED ON/ER is used to indicate the following functional states:
3.4.2
Function state of FlexRay interface
Function states of FlexRay channels (LEDs FLX1 and FLX2)
To display the function state of the FlexRay node, one LED is assigned to each
of the two FlexRay channels:
• LED
FLX1
: FlexRay channel A
• LED
FLX2
: FlexRay channel B
Meaning
LED ON/ER
State
Description
Power
Off
Off
Switched off
Green
Normal operat
-
ing mode
Active, operational
Error
Off
No error
Error-free function
Red
Functional error Return the module to
ETAS for repair.
Flashing red
(code 2)
Critical operat
-
ing state / soft
-
ware update is
active
Firmware update is
being performed. Do not
disconnect the module
from the PC!
Temperature in the
module is too high, func
-
tion is disabled.
LED FLX1
LED FLX2
Function state
Off
Off
FlexRay node inactive,
(FlexRay controller is not configured)
Flashing yellow
(code 1)
Off
FlexRay channel A active,
waiting for synchronization
Yellow
Off
FlexRay channel A active,
synchronized, ready for data exchange
Off
Flashing yellow
(code 1)
FlexRay channel B active,
waiting for synchronization