ES5392.1 High Current Switch Board (6-CH) - User’s Guide
36
Signals
ETAS
Block Diagram of the Analog Outputs of X1 PwrCtrl
Fig. 3-5
Block diagram of the analog outputs at X1 PwrCtrl
The pin assignment of X1PwrCtrl is located in Tab. 4-1 on page 41.
Technical Data of the Analog Outputs of X1 PwrCtrl
Tab. 3-1
Technical data of the analog outputs
3.4
Generic TTL Signals at X2 SwCtrl and X4 Power I/O Outputs
The connectors X2 SwCtrl and X4 Power I/O have generic digital TTL outputs that
can be used, e.g. to control external relays.
Digital Outputs DIG_OUT_X at X2 SwCtrl
The digital outputs DIG_OUT_0...DIG_OUT_5 at X2 SwCtrl have the following
properties:
• 6 TTL outputs, galvanically isolated, with common reference potential
GND_DIG_OUT
• Possibility for switching external relays
• Possibility for connection with an ES4408CON.1 (via CBV305.1-2 cable,
see also Fig. 1-2 on page 7)
• Configuration via RTIO
The pin assignment of X2 SwCtrl is located in Tab. 4-2 on page 42.
Output
Data
Output voltage
0 V to 10 V
Max. output current
10 mA
Resolution
14 bit
Accuracy
±10 mV
Galvanic isolation
yes
Overvoltage protection
up to ±60 V
WARNING!
The connector X2 SwCtrl is intended for connecting an ES4408.1
Load Chassis and does not offer overload protection.Connecting the
Switch Control outputs to non-intended devices may lead to the
destruction of the outputs or to an undefined behavior .
Analog Ground
(GND_ANA_OUT_X)
Analog Output
(ANA_OUT_X)
Overvoltage
Protection
DA
Converter
Galvanic
Isolation
FPGA
ES
5300
B
ackp
lan
e
Bessel
Lowpass
Filter
1 kHz
3dB