ETAS
ES430.1 - User’s Guide
67
To wire the module chain with additional current feeding
1. End the module chain after the last module whose power sup
-
ply is still guaranteed in the entire operational range.
2. Connect the combined Ethernet and power supply cable to the
“OUT” port of the last ES430.1 module of the chain towards the
PC.
3. Connect the combined Ethernet and power supply cable to the
“IN” port of the ES430.1 of the next module towards the end of
the chain.
4. Connect the supply voltage connector of the combined Ether
-
net and power supply cable to the desired power supply.
Note the color coding of the connectors.
6.7.2
“Sensor” Port
6.7.2.1
Bosch Lambda Sensor LSU4.9 (Code 1)
You can use different cables to connect the Bosch lambda sensor LSU4.9
(Code 1) to the ES430.1:
• Sensor cable CBAL451.1/ CBAL4515.1, equipped as follows (with analog
output):
– RB150 plug (Code 1) for the lambda sensor
– MC lamella connector for the supply of the sensor heating,
– BNC socket for analog output signals and
– input for an external signal for controlling the heater control when the
ES430.1 is on standby.
• Sensor cable CBAL452.1/ CBAL4525.1, equipped as follows:
– RB150 plug (Code 1) for the lambda sensor
– MC lamella connector for the supply of the sensor heating and
– input for an external signal for controlling the heater control when the
ES430.1 is on standby.
Power Supply
PC
Additional Power Supply