Commissioning
ES16x.1
-
User Guide
27
4.2.3
Manual Configuration of the Connection Speed (Automotive
Ethernet)
The connection speed of the Automotive Ethernet interface can be set manu
-
ally via a web interface.
1. Open a browser and enter the IP address of the module.
2. Click
Configure
.
3. Remove the checkmark at
Auto Config
in the area
AE
.
4. Mark the desired connection speed
(1000/100)
in the area
AE
SPEED
.
5. Click
Save
to confirm the input.
4.2.4
Resetting Data Loss Errors
If different speed settings exist in the two interfaces of the converter due to the
system configuration, with higher data throughputs this can result, in principle,
to data losses. This is not a device error. The devices display these losses via
the
Data Loss
LED (see Chapter “LEDs” on page
16).
1. Open a browser and enter the IP address of the module.
2. Click
Configure
.
3. Click
Clear Data Loss
or
4. Disconnect the module from the power supply.