![ETAS ES160.1 Скачать руководство пользователя страница 26](http://html.mh-extra.com/html/etas/es160-1/es160-1_user-manual_2431242026.webp)
ETAS
Commissioning
ES16x.1
-
User Guide
26
4.2
Web Interface
The connection mode
(Master/Slave/Auto)
and the connection speed
(100/
1000 Mbit/Auto)
to the Automotive Ethernet can be configured via a web inter
-
face. An Internet connection is not required.
4.2.1
Determining IP Address
You can determine the IP address of the module with the
HSP Update Tool
.
You can find the tool in the Download Center on the ETAS web page.
1. Start the
HSP Update Tool.
2. Search for the hardware with
<C
TRL
> + <
H
>
.
3. In the
Hardware
window, mark the desired module.
4. Open the
Properties
window with
<A
LT
> + <E
NTER
>
.
> In the
Properties
window under
Communication >
Communication Parameters
, you will find the IP address of
the module.
4.2.2
Manual Master-Slave Configuration
The Master-Slave configuration of the Automotive Ethernet connection can be
set manually via a web interface.
1. Open a browser and enter the IP address of the module.
2. Click
Configure
.
3. Remove the checkmark at
Auto Config
in the area
AE
.
4. Mark the desired mode
(Master/Slave)
in the area
AE
MODE
.
5. Click
Save
to confirm the input.
NOTE
The settings in the web interface are not saved permanently. If the module is
disconnected from the power supply, all settings are set back to the default
value.