ETAS
Technical Data
BR_XETK-S4.0
-
User
Guide
41
7.2.2
Measurement Data Memory
7.3
Configuration
7.4
Environmental Conditions
Inside the ECU housing the maximum. temperature is specified with 110°C, still
air.
Outside of the ECU housing the maximum ambient temperature is assumed to
be 105°C at 1m/s airflow.
Item
Characteristics
Location
Typically located within the emulation
memory when using DISTAB17
hooks. Measurement data memory
can be located in internal RAM.
Item
Characteristics
Configuration
Project-specific configuration for
- different microcontrollers or
- memory configurations
stored in EEPROM
Update
Logic devices updated using HSP
software
Item
Characteristics
Temperature range (operation, inside
ECU housing)
- 40
°C to +110
°C
- 40
°F to +230
°F
Temperature range (storage)
0
°C to +50
°C
- 18
°F to +122
°F
Relative humidity (non-condensing)
0 to 95%
Operating altitude
Max. 5000 m/ 16400 ft
Contamination level
2
Degree of protection
Determined by installation in ECU
Overvoltage category
(AC mains supply)
II
NOTE
Maximum Voltage to Earth or to any accessible parts (e.g., ECU Housing,
Vehicle Chassis) 60V DC / 30V AC.
NOTE
It is recommended to mount the BR_XETK-S4.0 via gap pad and mounting
bracket directly to the ECU housing.