background image

 

4.2

 

Alarm Rate:

 

The alarm rate can be set as fast or slow. The system comes with the fast rate set as the default. To change the 
alarm rate to SLOW, remove the jumper on “RATE/LENGTH ”. 
 

4.3 ARC(Automatic Resonance Control): 

Sometimes the system may alarm because of a resonance caused by either tagged merchandise being placed too 
close to the system or by an external condition that rings at a frequency within the transmitted signal band. While 
it is easy to move tagged merchandise beyond the detection area, external conditions may be intermitted or not 
easily found and corrected. The ARC circuitry helps in minimizing these effects. ARC is normally disabled. It may be 
activated by removing the jumper on “ARC” position 1. Activating ARC will cause the system to behave differently 
than when it is disabled. ARC will reduce the system sensitivity to a point where the offending resonance will no 
longer alarm the system. This will take from 20 seconds to over 1.5 minutes, depending upon the strength of the 
external resonance. A small resonance will take the smallest amount of time and a large resonance will take the 
most amount of time. The system will still work after ARC is activated, but will only respond to tags that present a 
greater signal level than the resonance. This means that the system’s sensitivity will be reduced, so the detection 
distance will be reduced. Noted that a large resonance may reduce the detection distance significantly. If the 
external resonance is removed, the system will recover and return to its normal sensitivity. Recovery time is 
approximately the same as activation time. Transitional resonance or tags will have little or no effect on system’s 
sensitivity. However, since the ARC function is controlled by external conditions, best sensitivity will usually occur 
when ARC is disabled(jumper on). 
 

4.4 FS(Frequency Select)

Another way to reduce the false alarms is by activating the FS feature. FS reduces the receiver bandwidth to 
exclude processing of any information received from the upper and lower frequency bands. Unlike ARC, the 
receiver sensitivity is not reduced except in these bands. Tag detection will not normally be affected. To activate FS, 
remove the jumper on “FS” position 1. While in tmay be can vary in frequency above and below 8.1 MHz, so 
normally pl do not use the FS function. If any tags frequency approaches the band edges, detection will be reduced. 
While the normal spread of tag frequencies is rather narrow, tags that are nearer the band edges may detect 
normally with FS deactivated but exhibit a shorter detection range if the FS jumper is removed. 
 

4.5

 

Automatic Level Control(ALC):

 

This function can help us to solve the problem that the label becomes disabled suddenly(maybe some systems will 
“kill” the label when the label is too close to the system). We can check if the system’s ALC is working properly by 
using the voltmeter to test the TPC voltage. The normal voltage of the test point is around 40V DC. The voltage of 
test point will reduce when we take the label close to the system, when we keep the distance between the label 
and system almost to zero, the voltage maybe will reduce to around 1V DC(the transimitted power reach to the 
lowest level). The voltage of test point will recover to the normal level automatically after we take the label away 
from the system.   
 

4.6 TP3D

TP2D and TP3D

:   

We can know the noise figure of surrounding environment by testing the TP2D voltage and TP3D voltage. The 
voltage of testing point is related to the noise figure of surrounding environment. The normal voltage range is 
70-90mv. It means that the noise is high when the voltage is more than the voltage range, there maybe are some 
strong noise source around. The electronic level of the test point shows the average value of the surrounding noise 

Содержание PG-308

Страница 1: ...版本号 xxx 颁布日期 2016 12 Edition V2 0 Issue date 16 05 21 PG 308 User Manual ...

Страница 2: ...t take apart any removable parts of the machine package Pay attention to the people around the machine especially the children Before maintenance and reparation the power supply should be turn off and the plug should be pull off Only professional personnel could repair the machine Pay attention not to stumble or kick off power supply plug Regularly check the power supply cable to make sure the cab...

Страница 3: ...bility Only our company engineer could repair or change the component of the machine During the maintenance please put a sticker on the machine shows maintenance no using Do not climb on the machine Do not contact the electric cable switch button of the machine by wet hand Before connecting the machine to the power supply please check if the voltage and frequency are same as the machine requiremen...

Страница 4: ...e to clean the metal tag If metal tag is damage please ask for one new from our company If the component which has metal tag is changed please use new metal tag on the new component part Warning Read and understand operator s manual and all other safety instructions before using this equipment Do not open the machine cover when the machine is running Do not use wet hand to contact any electric par...

Страница 5: ...store electronic store cosmetic store book store etc 3 1 Feature High class acrylic material sturdy and durable Simplicity design transparent and elegant Transmit receive integration by pulse technique Continuous work by low power consumption and its good performance Suitable the store which has multi exits and entrances or open type exits and entrances Easy to install and adjust Match for differe...

Страница 6: ...anning and label deactivate at the same time which is much more convenient for the cashier If using this kind of composing device we need pay much attention on the interferences between the deactivator and the laser barcode scanner then we just can get a good deactivation height If there are customers take the commodities without deactivation through the eas system the system will alarm then store...

Страница 7: ...r when ARC is disabled jumper on 4 4 FS Frequency Select Another way to reduce the false alarms is by activating the FS feature FS reduces the receiver bandwidth to exclude processing of any information received from the upper and lower frequency bands Unlike ARC the receiver sensitivity is not reduced except in these bands Tag detection will not normally be affected To activate FS remove the jump...

Страница 8: ...d jumper P3 With this function we can know the high voltage of TP2D and TP3D is resulting from the interference of active noise or the interference of passive noise When you pull up JP2 and JP3 at the same time if the voltage of TP2D and TP3D is reducing the most possible reason is there are labels or tags around if the voltage of TP2D and TP3D do not change it means that there are strong interfer...

Страница 9: ...s alarming 7 2 1 Any other electrical equipment are not allowed on the antenna power lines Please check the main switch in the switch board room check if it is sharing with other electrical equipment 7 2 2 Checking the antenna s surrounding if there are electrical equipment in 2 meters Such as lockers currency count machine doll machine freezer etc which circuits cannot be circularity 7 2 3 The ro...

Страница 10: ...gerous procedures please read the manual carefully before continuing the setting If not according to this manual operation may result product damage even personal injury If not according to this manual operation may result personal injury or property loss Before Assembling Before assembling the system please read the manual carefully Please contact with us if needed Checking contents before assemb...

Страница 11: ...ool 2 Phillips Acrewdrive Monkey Wrench Slotted Acrewdrive Diagonal 3M Tapeline Neele nose Pliers Oil Marker 16oz Claw Hammer 14 Percussion Bit Tuning wire of the control panel 102480 Cross recessed pan head screws M4 8mm P104 Explanation Screw 10MM Z676 Self locking Nut 10MM Z410 Gasket 10MM D560 Power Converter ...

Страница 12: ...ETAGTRON Detachment of the base 2 Cross Screwdrive r 102480 Cross recessed pan head screws M4 8mm 102480 Dismountin g Rotation Release ...

Страница 13: ...Fixed System Drilling Tool Oily Marke Positioning ETAGTRON Punch Hole P104 14 Percussion Bit 3M Tapcline 16oz Claw Hammer P104 Expansion Screw 10MM ...

Страница 14: ...System wire connection Monkey Wrench AlotType Screwdrive Fixing ETAGTRON Diagonal Pliers Nipper Z676 Locknut 10MM D560 Power Adaptor Z676 Z410 Wire connection Z410 Gasket 10MM ...

Страница 15: ...System Closure ETAGTRON 2 Phillips Screwdrive r 102480 Cross recessed pan head screws bolt with gasket M4 8mm Closing the cover Resetting 102480 ...

Страница 16: ... Knob Clockwise increase Counterclockwise decrease mis alarming may appear if there are lots Gain System tuning 1 ETAGTRON Gain adjustment Gain adjustment Knob Clockwise maximum volume Counterclockwise minimum volume ...

Страница 17: ... tuning2 ETAGTRON Forbid transmitting antenna P2 up loop emission control ON default OFF P3 down loop emission control ON default OFF RATE alarm rate ARC auto threshold FS frequency choose LENGTH alarm length ...

Страница 18: ...be in a normal sensitivity Restore and activate time are the same The occasional interference or label to system s sensitivity is rarely influenced or no influence at all Of course because the ARC function is controlled by external environment when the ARC function is off the system will have the best sensitivity Frequency selection FS The other one way of reducing the false alarming is activating...

Отзывы: