Concluding activities
21
7
Concluding activities
Checking the drive connection data in the control
system
Check the connection data of the drive based on the
settings in the control system. The connection data is
listed on the name plate of the motor. The parameters
for the drives of the discharge are shown in the text
menu of the respective boiler:
The parameters for the drive of the agitator are shown
in the text menu of the function block [Agitator]:
Checking the drive's direction of rotation
Mark the drive by drawing a line over the screw,
washer and drive.
Fig. 7-1: Marking
In the function block of the boiler, switch to the inputs
and outputs menu. Select the stoker unit [Stoker unit]
and press the
button for manual operation. Only
start the discharge drive with the [Fwd] button.
Fig. 7-2: Menu for manual operation
Check the direction of rotation of the drive with the aid
of the marking. The correct rotation direction is shown
in the following diagram.
If the rotation direction is not correct, check the drive's
electrical connection.
Fig. 7-3: Correct direction of rotation
Outputs
Stoker unit
Intermediate conveyor screw
Current
Max. current
NominCurr
Outputs
Agitator drive
Current
NominCurr
Max. current
Содержание Twin Screw Agitator
Страница 1: ...2020 09 16 EN 0000000311 V 005 X 50 0 93123 001 Twin Screw Agitator Operating Instructions ...
Страница 6: ...6 www eta co at Technical data 2 Technical data Fig 2 1 Side view Fig 2 2 Top view ...
Страница 23: ...Circuit diagram 23 8 Circuit diagram ...
Страница 26: ...www eta co at ...
Страница 27: ......
Страница 28: ...www eta co at www eta co at downloads DOWNLOAD ...