ETAtouch controller
[Boiler] function block - PE-K
31
temperature for measurement purposes. By pressing
the [Start now]
button, the boiler will immediately
begin preparations for a subsequent measurement.
Fig. 5-44: Settings window for emission measurement
In addition, the locking time of the boiler can be
adjusted in the settings window (
[Lock duration]
button). This relates to the set time of the measure-
ment. During this period no heating operation will be
started, so that the heating system has time to cool
down.
Example: If a time of 17:00 is set for the emission
measurement and at [Lock duration] 8 h, heating will
end at 09:00 .
The [Deactivate measurement]
button ends the
emission measurement and switches the boiler back to
normal mode.
Settings menu
In the settings menu (
[Settings] button in the
overview), the following functions and parameters can
also be set:
[Fill-up time] button
This sets the daily time for complete refilling of
the boiler pellet bin if pellets have been used.
This prevents refilling during the night. This
time applies for every day of the week.
[Hopper Fill] button
This fills the reservoir on the boiler immediately,
independent of the suction time settings.
5.2.2
Text menu - Adjustable parameters
Adjustable parameters
Detailed descriptions of the parameters are provided
below.
Explanation of [Begin idle time WT cleaning] and
[Idle time during WT cleaning]
The [Idle time during WT cleaning] parameter is used
to select the duration of the idle time for heat
exchanger de-ashing. The start time for the idle time is
set with the [Begin idle time WT cleaning] parameter.
The idle time should be kept as short as possible.
Explanation of [De-ash after min.] and [De-ash
after max.]
The boiler's de-ashing interval is set with the [De-ash
after min.] and [De-ash after max.] parameters. The
boiler de-ashes within the range specified by these two
parameters.
The de-ashing interval may only be modified after
consultation with a specialist or ETA customer
service.
Explanation of [De-ash after min.] and [De-ash
after max.]
The boiler's de-ashing interval is set with the [De-ash
after min.] and [De-ash after max.] parameters. The
boiler de-ashes within the range specified by these two
parameters.
The de-ashing interval may only be modified after
consultation with a specialist or ETA customer
service.
Boiler
Ash removal
Begin idle time WT cleaning
Idle time during WT cleaning
De-ash after min.
De-ash after max.
Empty ash box after
Содержание 13180LP-T
Страница 1: ...2018 05 24 EN 0000000313 V 005 3 43 0 3308 93222 001 Pellet boiler 180 220 kW Operation ...
Страница 29: ...ETAtouch controller Getting to know the control system 29 ...
Страница 39: ...ETAtouch controller BufferFlex function block 39 ...
Страница 47: ...ETAtouch controller Buffer function block 47 ...
Страница 51: ...ETAtouch controller Hot water tank function block 51 ...
Страница 55: ...ETAtouch controller Fresh water module function block 55 ...
Страница 69: ...ETAtouch controller Solar function block 69 ...
Страница 87: ......
Страница 88: ...www eta co at www eta co at downloads DOWNLOAD ...