Technical Specifications
2
ET System electronic GmbH
TECHNICAL SPECIFICATIONS
I
NPUT
S
PECIFICATION
:
Device Power
5kW
10kW
15kW
20kW
30kW
45kW
60kW
Connection
Input 1P/230
Input 3P/200
Input 3P/209
Input 3P/400
Input 3P/440
Input 3P/480
Max allowed non
symetry
(3P-Systeme)
Input current
1,2
1P/230 Modell
33 A eff
X
14
X
14
X
14
X
14
X
14
X
14
Input current
1,2
3P/200 Modell
25 A eff
50 A eff
74 A eff
99 A eff
148 A eff
221 A eff
295 A eff
Input current
1,2
3P/208 Modell
23 A eff
46 A eff
69 A eff
92 A eff
138 A eff
207 A eff
276 A eff
Input current
1,2
3P/400 Modell
11,5 A eff 22,9 A eff 34,4 A eff 45,8 A eff 68,7 A eff 103,1 A eff
137,5 A eff
Input current
1,2
3P/440 Modell
11 A eff
21 A eff
32,5 A eff
42 A eff
63,5 A eff
95 A eff
127 A eff
Input current
1,2
3P/480 Modell
10 A eff
19,5 A eff
30 A eff
39 A eff
58 A eff
87 A eff
117 A eff
Nominal current
Internal Fuse
3P/400 Modelle
15 A
30 A
45 A
60 A
90 A
135 A
180 A
Recommended Supply
breaker 3P/400 Model
(value and curve)
16A
Type D/K
32A
Type D/K
63A
Type D/K
63A
Type D/K
80A
Type D/K
120A
Type D/K
150A
Type D/K
Leakage current
cos phi
Harmonic content
3
Efficiency Type
50Hz = 72% / 100Hz = 2% / 150Hz = 0,9% / 200Hz = 0,1% / 250Hz = 11% / 350Hz = 0,6%
94%
<153 A
<229 A
3 x 440VAC (396-484VAC 47-63Hz)
3 x 480VAC (432-528VAC 47-63Hz)
< 3%
<305
<35 mA
>0,7
Inrusch
transientcurrent
2
<25 A
<51 A
<76 A
<102 A
3 x 400VAC (360-440VAC 47-63Hz)
LAB/HP/E
3 Leitungen (1P+N+E) / 5 Leitungen (3P+N+E)
1 x 230VAC (207-253VAC 47-63Hz)
3 x 200VAC (180-220VAC 47-63Hz
3 x 208VAC (187-229VAC 47-63Hz)
1 For nominal current and voltage
2 For nominal input voltage
3 Total harmonic distortion input current ([%] I in)
4 250A is the maximum possible current for an 5kW Unit
5 If the ripple is not specified, maximum allowed ripple is 0,2% of F.S.
6 The measurement of the peak peak ripple is strongly dependent of the measurement setup
7 The given accuracy is also all interfaces valid
9 Higher number is possible, ask manufacturer
11 The ripple measurment methode of ET-System is specified at application note „ET Ripple-Spec. (Page 32)
12 The ripple specification is reservation to change on the part of manufacturer
13 Device is at the moment only available with highspeed output (Low output cap.)
14 Not as standard Unit available
Содержание LAB-HP/E 10KW
Страница 2: ...Software version V15 November 2016...
Страница 5: ......
Страница 6: ......
Страница 10: ...4 ET System electronic GmbH IMPORTANT SAFETY INSTRUCTIONS...
Страница 12: ...Important Safety Instructions 6 ET System electronic GmbH...
Страница 40: ...Notes 34 ET System electronic GmbH NOTES...
Страница 41: ...Notes ET System electronic GmbH 35...