![ESYLUX DEFENSOR TS Скачать руководство пользователя страница 32](http://html1.mh-extra.com/html/esylux/defensor-ts/defensor-ts_operating-instruction_2430048032.webp)
GB
32 / 34
MA01709900
Technical data
9.2 Troubleshooting
Fault
Cause
The lighting does not switch
on automatically
- The level of ambient light is above the
configured brightness switching value
- Lighting has been switched off manually
-
Time-dependent operating modes
are set
The lighting does not switch
off automatically
-
Time-dependent operating modes
are set
The lighting switches off
when it gets dark
- The level of ambient light is above the
configured brightness switching value
- Lighting has been switched off manually
-
Time-dependent operating modes
are set
Buttons do not work
- Device is still in the warm-up phase
- The push button was used without the
neutral conductor connected
- The push button is not routed to the
S terminal
Twilight switch
does not respond
- No power supply; check the
mains voltage.
10. Technical data
Attachment
Installation type
Layout
Installation position
Wall
Connection
NYM 3 x 1.5 mm² ... NYY 5 x 2.5 mm²
Ø min. 2 x 9 mm ... Ø max. 2 x 15 mm
Housing
Dimensions
92 mm x 108 mm x 46 mm
Weight
TS
168 g
TS T
172 g