background image

Security at Fingertips

www.esslsecurity.com

Содержание inBIO460 Series

Страница 1: ...Security at Fingertips www esslsecurity com...

Страница 2: ......

Страница 3: ...ction and Installation 8 3 1 Panel Box Installation 8 3 2 Installation and Wiring 9 3 3 System Structure 10 3 4 Connection Terminals 12 3 5 Connection with External Accessories 16 3 6 Connection with...

Страница 4: ...lest the equipment should fall and get damaged and more undesirably cause severe personal injuries Therefore it is important to install the equipment as instructed by the manufacturer 4 All periphera...

Страница 5: ...he manufacturer 9 Security inspection After the equipment is repaired the repair personnel are supposed to conduct security inspection to ensure the equipment can work normally 10 Power supply Operate...

Страница 6: ...ommended not to connect any other auxiliary devices without permission Before all non routine operations must communicate with our engineers in advance 5 A control panel should not share one power sup...

Страница 7: ...induced electromotive force generated by an electronic lock at the instant of switching off on it is necessary to connect a diode in parallel please use the FR107 delivered with the system with the el...

Страница 8: ...y or four door one way access control A maximum of 30 000 card holders and 100 000 offline event records Support of multiple Wiegand card formats and a password keypad compatible with various types of...

Страница 9: ...185 1mm length 106mm width 36mm thickness for inBIO160 260 226mm length 106mm width 36mm thickness for inBIO460 External box dimensions 400mm 330mm 90 5mm 2 3 Indicators Description When the inBIO160...

Страница 10: ...ellow green Flash state indicates it is sending or receiving data through RS485 communication 5 CARD indicator yellow Flash state indicates card is punched on reader See the indicators in the followin...

Страница 11: ...3 Connection and Installation 3 Connection and Installation 3 1 Panel Box Installation Installation steps for the control panel Appearance and Internal of the panel box 8...

Страница 12: ...n make sure the power supply is disconnected Any operation with power connected will cause severe damage to the equipment 2 The access control wires must be separated according to heavy and light curr...

Страница 13: ...inBIO460 System Structure Note The diagram above takes the inBIO460 for example By contrast only one door two way access is applicable to the inBIO160 system only 10 Installation Guide for inBIO460 S...

Страница 14: ...ol panels preferably fewer than 32 The communication wires should be kept away from high voltage wires as far as possible and should be neither routed in parallel with nor bundled with power wires A m...

Страница 15: ...3 4 Connection Terminals inBIO160 terminal connection diagram 12 Installation Guide for inBIO460 Series Control Panel...

Страница 16: ...3 Connection and Installation inBIO260 terminal connection diagram 13...

Страница 17: ...inBIO460 terminal connection diagram 14 Installation Guide for inBIO460 Series Control Panel...

Страница 18: ...detectors etc 2 The auxiliary output may be connected to alarms cameras door bells etc 3 All the terminals software Please see the respective software instructions for details Terminals on the C3 con...

Страница 19: ...door When you press the button the door will be opened An exit button is fixed at a height of about 1 4 meter above the ground Ensure it is located in the right position without slant and its connecti...

Страница 20: ...ories Note The diagram above takes inBIO460 for example By contrast inBIO160 provides one auxiliary input interface inBIO260 provides two and inBIO460 provides four 3 6 Connection with Readers The con...

Страница 21: ...e 485 address device number of reader by software DIP switch or keypad method Such as the reader 1 2 the odd number is for enter reader and the even number is for exit reader for example the 485 addre...

Страница 22: ...y or four door one way mode The Wiegand interfaces provided by the inBIO series can be connected to different types of readers If your card reader does not use the voltage of DC 12V an external power...

Страница 23: ...User Manual A lock relay can be connected in the dry and wet modes while an auxiliary output relay cannot The following illustrates relay output connection with an example of door connection 1 An acce...

Страница 24: ...he max connected lock is 4 4 To protect the access control system against the self induced electromotive force generated by an electronic lock at the instant of switching off on it is necessary to con...

Страница 25: ...3 Dry mode External power supply for NO Lock 4 Dry mode External power supply for NC Lock 22 Installation Guide for inBIO460 Series Control Panel...

Страница 26: ...3 Connection and Installation 5 Dry mode NO Lock under the binary value control 6 Dry mode NC Lock under the binary value control 23...

Страница 27: ...24 Installation Guide for inBIO460 Series Control Panel...

Страница 28: ...3 Connection and Installation 3 8 System Power Supply Structure An access control operator panel is powered by 12V DC Generally to reduce 25...

Страница 29: ...pectively To prevent power failure of a control panel from making the whole system unable to work normally the access control management system is usually required to have one UPS at least and access...

Страница 30: ...electronic lock during an action on other elements 4 core wires RVV 4 0 75mm2 two for a power supply and two for door sensor are recommended 5 For EXT485 communication we suggest to use 4 conducotor...

Страница 31: ...water pipes to ensure reliable grounding of the connection between the shielding layers of data cables and the metal troughs or pipes Note that a shielding enclosure can have a shielding effect only w...

Страница 32: ...ed twisted pairs which prove effective to prevent and shield interference RS485 communication wires should be connected by means of bus cascade instead of in a star form to achieve a better shielding...

Страница 33: ...ting place 8 of the DIP switch to the ON position is equivalent to parallel connection of one 120ohm resistance between the 485 and 485 lines As shown in the figure below put number 8 of the DIP switc...

Страница 34: ...nd 6 to ON position as illustrated below 485 address setting table Switch Setting Place Address 1 2 3 4 5 6 Address No 1 2 4 8 16 32 01 ON OFF OFF OFF OFF OFF 02 OFF ON OFF OFF OFF OFF 03 ON ON OFF OF...

Страница 35: ...FF 27 ON ON OFF ON ON OFF 28 OFF OFF ON ON ON OFF 29 ON OFF ON ON ON OFF 30 OFF ON ON ON ON OFF 31 ON ON ON ON ON OFF 32 OFF OFF OFF OFF OFF ON 33 ON OFF OFF OFF OFF ON 34 OFF ON OFF OFF OFF ON 35 ON...

Страница 36: ...61 ON OFF ON ON ON ON 62 OFF ON ON ON ON ON 63 ON ON ON ON ON ON 2 Restoring factory setting The silk screened 7 number 7 of the DIP switch is the switch for restoration of system settings The switch...

Страница 37: ...between 485 and 485 34 Installation Guide for inBIO460 Series Control Panel...

Страница 38: ...24 Shambavi Building 23rd Main Marenahalli JP Nagar 2nd Phase Bangalore 560078 Phone 91 8026090500 Email sales esslindia com www esslsecurity com...

Отзывы: