Essilor Instruments Vision-C 600 Скачать руководство пользователя страница 1

U

SER

 

MANUAL

Содержание Vision-C 600

Страница 1: ...USER MANUAL...

Страница 2: ...screen 19 b Adjusting optotypes from console 21 IV UPDATE THE SCREEN 28 1 Update by USB key 29 2 By LAN IP 32 V TROUBLESHOOTING 35 VI TECHNICAL DATA 37 VII CAUTIONS WARNINGS 39 1 Exclusion of liabili...

Страница 3: ......

Страница 4: ...I INTRODUCTION...

Страница 5: ...it radio frequency energy which may interfere with radio communications if the device is not installed and used in strict conformity with manufacturer instructions However there is no guarantee that t...

Страница 6: ...sed in complete safety Indicate the humidity limits to which the medical device can be exposed in complete safety Indicate the limits of atmospheric pressure to which the medical device can be exposed...

Страница 7: ...II INSTRUMENT...

Страница 8: ...sories are included Standard accessories and detachable parts Power supply Ethernet cable 2m Power cable 1 80m x2 US ref CA6096 Europe ref VRSA05 Wall mounting bracket Power cable holder User manual D...

Страница 9: ...me temperatures and humidity levels likely to undergo strong oscillations or sudden shocks Do not use the instrument with flammable anaesthetics or in conjunction with flammable agents The instrument...

Страница 10: ...view or mirror arrangement 2 Level the supplied wall mount bracket with the metal tabs facing up and out on your wall and mark the holes for the installation 3 Place the wall mount bracket on the wall...

Страница 11: ...s Screen plate ion plate x1 Wall plate Screw M4x16mm ref CV6273 x4 Fastening screw ST6 3 65 vmm x2 Expansion pipe x2 Washer x2 USER MANUAL INSTRUMENT 11 Vision C 600 Polarized visual chart system V1 0...

Страница 12: ...the part to be fixed on the wall Position the wall part in order to mark the 2 fixing pants then drill Fit the wooden dowel provided Screw the wall part of the support USER MANUAL INSTRUMENT Vision C...

Страница 13: ...with the 4 screws ref CV6273 M4x16mm Position the screen from above as shown below Screw the security screw Adjust the screen angle as needed USER MANUAL INSTRUMENT 13 Vision C 600 Polarized visual ch...

Страница 14: ...on a support ref CS510 Installation of the power cord holder Put the power cable mounting holder Screw the support to the right location The scew is supplied USER MANUAL INSTRUMENT Vision C 600 Polari...

Страница 15: ...tions please refer to the specifications contained in this document Keep the original packaging with care in case the device needs to be transported again 5 Identification and locating of the elements...

Страница 16: ...White LED test Maddox Rear face 1 Aeration 2 Speaker 3 Fixation zone 4 Aeration Connection 1 Power switch ON OFF 2 Power IN DC 12V 3 RH45 Lan 4 USB1 5 USB2 USER MANUAL INSTRUMENT Vision C 600 Polariz...

Страница 17: ...III ADJUSTMENTS BEFORE THE EXAMINATION...

Страница 18: ...console keypad and the screen by clicking on the optotypes they should appear on the screen Turn off the instrument Press the ON OFF switch on the chart screen The screen switch on The instrument is...

Страница 19: ...All the Vision C 600 settings are configured on the console of the Vison R It is possible to modify the default settings of the screen by pressing on of the console The instrument settings page is dis...

Страница 20: ...Type is set on Vision C 600 the IP communication is available If the IP communication is set IR Channel is replaced by IP Address When Vision C 600 is selected Time before eco mode and Time before scr...

Страница 21: ...in order to test the connection Once the adjustments are made press on to confirm to cancel b Adjusting optotypes from console By IR It is possible to generate optotypes from console by pressing on o...

Страница 22: ...horopter head to the screen in Far Exam Distance menu Insert a USB key on the side of the console or directly on the power supply Select on the screen The following page appears USER MANUAL ADJUSTMENT...

Страница 23: ...f the chart screen Switch on the screen The process starts A warning popup appears Press on to confirm The optotypes are adjusted The update will start automatically USER MANUAL ADJUSTMENTS BEFORE THE...

Страница 24: ...ssing on of the keyboard of the console Then click on Set the mirror mode OFF or ON regarding your configuration The chart screen will restart automatically The following page appears USER MANUAL ADJU...

Страница 25: ...set the distance from phoropter head to the screen in Far Exam Distance menu Select on the screen Press on to start the update The following page appears USER MANUAL ADJUSTMENTS BEFORE THE EXAMINATIO...

Страница 26: ...ading and upgrading the software Then the system reboots The message Waiting chart screen appears on the keyboard USER MANUAL ADJUSTMENTS BEFORE THE EXAMINATION Vision C 600 Polarized visual chart sys...

Страница 27: ...9 10 Don t do anything At the end of the update press on The system reboots a second time USER MANUAL ADJUSTMENTS BEFORE THE EXAMINATION 27 Vision C 600 Polarized visual chart system V1 02 2021 VRSQSE...

Страница 28: ...IV UPDATE THE SCREEN...

Страница 29: ...ing the one of the Vision C 600 1 Update by USB key Click on of the console Then click on Set the Link setting with IR Then click on Insert a USB key on the side of the console or directly on the powe...

Страница 30: ...Connect the USB key on one of the USB port of the chart screen The process starts A warning popup appears Press on to confirm The optotypes are adjusted USER MANUAL UPDATE THE SCREEN Vision C 600 Pola...

Страница 31: ...ch on the screen Remove the USB key The update will start automatically The chart screen will restart automatically USER MANUAL UPDATE THE SCREEN 31 Vision C 600 Polarized visual chart system V1 02 20...

Страница 32: ...k on of the console Then click on Set the Link setting with IP Then click on The following page appears The following page appears USER MANUAL UPDATE THE SCREEN Vision C 600 Polarized visual chart sys...

Страница 33: ...the screen Press on to start the update The Vision 600 is downloading and upgrading the software Then the system reboots USER MANUAL UPDATE THE SCREEN 33 Vision C 600 Polarized visual chart system V1...

Страница 34: ...g At the end of the update press on The message Waiting chart screen appears on the keyboard The system reboots a second time USER MANUAL UPDATE THE SCREEN Vision C 600 Polarized visual chart system V...

Страница 35: ...V TROUBLESHOOTING...

Страница 36: ...ouches the pins Restart the product and in the case that it starts replace all the covers back on If the product does not turn on contact your local technical support If the problem has not been resol...

Страница 37: ...VI TECHNICAL DATA...

Страница 38: ...A power adaptor Model GSM60A12 P1J Power consumption Less than 60VA Communication Wire Ethernet Wireless IR DA Communication Dimension and weight Length 393 6 mm Width 612 mm Depth 71 3 mm Total weigh...

Страница 39: ...VII CAUTIONS WARNINGS...

Страница 40: ...nce activities are not under the control of Essilor They are therefore the sole responsibility of the customer Essilor declines any responsibility in the matter as indicated below The sale of products...

Страница 41: ...r plug with wet hands This may cause an electric shock If you do not use the instrument for an extended period disconnect the power cord from the outlet Do not use multi socket power strips adapters o...

Страница 42: ...ce is defined in clause 16 5 of IEC 60601 1 Connecting this instrument to a computer network that includes other equipment may result in safety and data protection risks The responsible organization i...

Страница 43: ...the applicable electromagnetic compatibility standards however the user must ensure that any electromagnetic interference does not create an additional risk such as radio frequency transmitters or ot...

Страница 44: ...ion IEC61000 3 2 Class A Complies Voltage variations voltage fluctuations and flicker IEC61000 3 3 Complies d Magnetic and electromagnetic immunity The product is intended for use in the electromagnet...

Страница 45: ...adio frequency including 80 MA at 1 KHz 4 Cleaning Maintenance In order to ensure safety and the performance of the instrument all maintenance operations unless otherwise specified in this manual must...

Страница 46: ...see chapter Adjustments before the examination 6 If the equipment does not operate properly you are recommended to do as below Check model name and serial number of the equipment and contact your Essi...

Страница 47: ...VIII QR CODE...

Страница 48: ...USER MANUAL QR CODE Vision C 600 Polarized visual chart system V1 02 2021 VRSQSE 48...

Страница 49: ...USER MANUAL QR CODE 49 Vision C 600 Polarized visual chart system V1 02 2021 VRSQSE...

Страница 50: ...USER MANUAL QR CODE Vision C 600 Polarized visual chart system V1 02 2021 VRSQSE 50...

Страница 51: ...Essilor Instruments USA 8600 W Catalpa Avenue Suite 703 Chicago IL 60656 Phone 855 393 4647 Email info essilorinstrumentsusa com www essilorinstrumentsusa com...