When shipped from the factory, the Essex Hand-E-Tap Series Switch has been pre-programmed with 
the most common settings for typical applications.  The unique feature of the Hand-E-Tap is that it is 
field programmable for a variety of access control applications depending on specific needs.  Please 
refer to the operating device specifications for application requirements.  

-----Factory Default Settings----- 

Relay On Time

 – The Hand-E-Tap has been pre-programmed for a 5 second output. When the switch is tapped, the relay 

is activated for 5 seconds (N/O or N/C depending upon installation wiring). This setting can be changed from 1 to 60 

seconds or toggled to tap on and tap off.  Refer to Section 1 for changing factory relay settings. 

Tap Sensitivity

 – The Hand-E-Tap can be set to various levels of tap sensitivity.  Factory default setting is a 

light

 tap 

which requires less pressure to activate.  This sensitivity can be set requiring more or less pressure to activate.  Refer to 

Section 2 for sensitivity settings. 

LED Settings

 – The LED’s have been preset to normally off (no illumination while the Hand-E-Tap is inactive).  When 

the faceplate is tapped and the relay is on, the LED’s will alternately flash.   A variety of LED settings are available in 

Section 3 of this guide. 

Audio Beeper Settings

 – The Hand-E-Tap is factory set to beep once every second the relay is activated. The Hand-E-Tap 

is field programmable to change the setting frequency, turn off audio, or programmed to utilize the “finder mode” function. 

The “finder mode” provides a beep once every 10 seconds announcing the Hand-E-Tap location for sight impaired users. 

To change audio settings and to activate the “finder mode”, refer to Section 4. 

-----Customizing the Settings----- 

Section 1 - 

RELAY ON TIME SETTING

 

The relay on time setting can be adjusted from 1 to 60 seconds or toggled to tap on and tap off.  Press and hold the program 

button #3 on the back of the Hand-E-Tap.  After 5 seconds you will hear 3 beeps indicating you are at the “0” setting. If 

you wish to utilize the tap on – tap off feature, simply release the program button.  To set an output time, press the program 

button for the desired seconds (1 per second).  When finished, wait 5 seconds and the Hand-E-Tap will beep 3 times 

confirming the settings. 

Example:  To set relay for a 4 second on time, press and hold the program button (#3) for 5 seconds.  After hearing 3 

confirmation beeps, release button and press 4 times and release. After about 5 seconds you will hear 3 confirmation beeps 

indicating setting is complete. NOTE:  Do not let more than 5 seconds elapse between presses or system will reset. 

Section 2

 - 

PROGRAMMING TAP SENSITIVITY

 

The Hand-E-Tap can be set to various levels of tap sensitivity.  Factory default setting is a 

light

 tap which requires less 

pressure to activate.  This can be set up for minimum sensitivity requiring more pressure to activate. Press buttons 2 and 3 

at the same time on the back of the Hand-E-Tap to program tap sensitivity.  A double beep indicates they are both pressed. 

 Hold for 5 seconds to enter programming mode (3 beeps) then release.

 

 

Press button 1 for minimum (hard) tap sensitivity                                                                                                                                     

Press button 2 for mid tap sensitivity                                                                                                                                                          

Press button 3 for maximum (easy) tap sensitivity (default)

 