Use, Care, and Installation Guide
www.zephyronline.com
Model number:
Serial Number:
Date of Purchase:
Sales Dealer:
AUG12.0401 © Zephyr Corporation
Breeze I
AK1124x, AK1100x, AK1136x
Breeze II
AK1200x, AK1236x
READ AND SAVE THESE INSTRUCTIONS
Страница 1: ...stallation Guide www zephyronline com Model number Serial Number Date of Purchase Sales Dealer AUG12 0401 Zephyr Corporation Breeze I AK1124x AK1100x AK1136x Breeze II AK1200x AK1236x READ AND SAVE THESE INSTRUCTIONS ...
Страница 2: ...www zephyronline com ...
Страница 3: ... Specifications 8 Preparing Electrical 9 Preparing Electrical and Ducting 10 Converting to Air Recirculating Mode 11 12 Mounting the Range Hood 13 FEATURES CONTROLS Controls Features 14 MAINTENANCE Cleaning and Filter Removal 15 Lights 16 TROUBLESHOOTING 17 WIRING DIAGRAMS 18 LIST OF PARTS AND ACCESSORIES 19 Table of Contents ...
Страница 4: ...ONS IN THE EVENT OF A RANGE TOP FIRE OBSERVE THE FOLLOWING a SMOTHER FLAMES with a close fitting lid cookie sheet or metal tray then turn off the burner BE CAREFUL TO PREVENT BURNS If the flames do not go out immediately EVACUATE AND CALL THE FIRE DEPARTMENT b NEVER PICK UP A FLAMING PAN You may be burned c DO NOT USE WATER including wet dishcloths or towels a violent steam explosion will result d...
Страница 5: ...es It is the customer s responsibility To contact a qualified electrical installer To assure that the electrical installation is adequate and in conformance with National Electrical Code ANSI NFPA 70 latest edition or CSA standards C22 1 94 Canadian Electrical Code Part 1 and C22 2 No 0 M91 latest edition and all local codes and ordinances If codes permit and a separate ground wire is used it is r...
Страница 6: ...35W pre installed 1 3 1 4 x 10 rectangular starting collar with damper located inside hood body 1 Hardware package HARDWARE PACKAGE CONTENTS PARTS NOT SUPPLIED Ducting conduit and all installation tools Cable connector if required by local codes Recirculating Kit 0AK11 21001 M4 x 1 4 M4 x 1 1 2 4 M4 x 2 4 M4 x 8 10 Wood screw washers 4 Wire Caps 3 Light bulb removal Suction Cup 1 ...
Страница 7: ... Ft 6 Round straight 1 Ft x Ft Subtotal column 1 Duct pieces T otal Equivalent number length x used 6 Round wall cap with damper 30 Ft x Ft Round wall cap with damper 30 Ft x Ft 7 10 Round 900 elbow 15 Ft x Ft 7 10 7 10 Round 450 elbow 9 Ft x Ft Ft Ft Ft 6 Round roof cap 30 Ft x Ft 7 10 Round roof cap 30 Ft x Ft Subtotal column 2 Subtotal column 1 Total ductwork 6 roundto 3 1 4 x 10 rect transitio...
Страница 8: ... no higher than 32 It is important to install the hood at the proper mounting height Hoods mounted too low could result in heat damage and fire hazard while hoods mounted too high will be hard to reach and will lose its performance and efficiency If available also refer range manufacturer s height clearance requirements and recommended hood mounting height above range Vertical Ducting 3 1 4 x10 mi...
Страница 9: ... exhaust must be ducted to the outside Use metal ductwork only Fasten all connections with sheet metal screws and tape all joints with certified Silver Tape or Duct Tape Some Ducting Options Installation Ducting Options Roof Pitch w Flashing Cap Rear Ducting 3 1 4 x10 vertical ducting 3 1 4 x10 horizontal ducting Air Recirculating ...
Страница 10: ... 29 15 16 30 23 15 16 24 33 7 8 36 27 7 8 30 22 1 16 24 33 5 8 36 27 5 8 30 21 5 8 24 2 3 4 C L 8 5 8 1 3 8 9 1 16 2 12 3 16 10 7 8 3 4 9 1 16 elec k o elec k o 5 1 2 14 3 8 19 5 16 20 3 32 TOP BACK SIDE 1 2 1 2 10 3 1 4 10 3 1 4 C L Air Recirculating Louver Plate ...
Страница 11: ...ectrical Supply This appliance requires a 120V 60Hz electrical supply and connected to an individual properly grounded branch circuit protected by a 15 or 20 ampere circuit breaker or time delay fuse Wiring must be 2 wire w ground Please also refer Electrical Diagram labeled on product AK11xxx 152 Watts 1 35 Amps AK12xxx 167 Wats 1 5 Amps Cable Lock A cable locking connector not supplied might als...
Страница 12: ...res through the cable lock Some local codes require the use of a cable lock check your local codes 4 If using hood in air recirculating mode skip steps 4 and 5 Pry open desired 3 1 4 x 10 ducting knock out either on top or back of hood 5 Secure 3 1 4 x 10 starting collar with damper to the duct opening using 10 M4x8 screws Installation Preparing Electrical and Ducting 10 www zephyronline com ...
Страница 13: ...ure charcoal filter holder to safety grill body by lifting up on spring clips and twisting The clip should cover the lip of the charcoal filter holder securely 4 Remove each screw from recirculating top plate Plate is located on top of hood towards the front NOTE Skip the recirculating preparation pages if you are ducting the air out of your home Recirculating preparation continued on next page In...
Страница 14: ...Remove each of the 5 screws holding the 2 interior recirculating panels 6 Remove 2 interior recirculating panels 7 Place louvered recirculating plate over top opening and secure using the screws previously removed NOTE Skip this page if you are ducting the air out of your home ...
Страница 15: ... and mark the mounting holes duct and electrical locations with a pencil 5 Drill cut out the required openings for duct and electrical access by following the dimensions on page 8 make sure the duct opening is large enough to apply duct tape 6 Fasten hood onto cabinet with 4 M4 wood screws with washers provided 7 Install electrical 8 Install duct work and seal with duct tape 9 Reinstall filters an...
Страница 16: ... more time to shut them off This button will change the speed setting of the motors By pushing it you will change the speeds from high to medium to low This button will put the hood into delay off mode When pushed the hood will switch to the lowest speed and the entire hood will shut down all functions after 5 minutes This switch turns the blower on and off and controls the speed selection is off ...
Страница 17: ...with grain Aluminum Mesh Filters The aluminum mesh filters are intended to trap residue and grease from cooking Although the filters should never need replacing they are required to be cleaned every 30 days or more often depending on cooking habits Filters may be placed in dishwasher at low heat or soaked in hot soapy water Dry filters and re install before using hood Removing Aluminum Mesh Filter...
Страница 18: ...unter clockwise Note Bulb does not unscrew it turns 60 degrees stops and falls out If bulbs are difficult to turn due to prolonged use firmly attach a glass suction cup approximately the diameter of the bulb or use a rubber latex glove and turn counter clockwise Replacement bulbs are available at most hardware stores or from Zephyronline com Purchase type MR16 GU 10 35W halogen For Zephyr part num...
Страница 19: ...heel 2 Change the blower wheel 3 The hood is not secured in place 3 Check the installation of the hood The unit is whistling 1 The filter is not in the correct position 1 Adjust the filters until the whistling stops 2 The duct pipe connections are not sealed or connected properly 2 Check the duct pipe connections to be sure all connections are sealed properly The blower is working but the lights a...
Страница 20: ...18 www zephyronline com Wiring Diagrams ...
Страница 21: ...ter 24 hoods each 50200013 Metal Filter 30 and 36 hoods each 50200012 Optional Accessories Recirculating Kit 0AK11 21001 Replacement Charcoal Filters 2pk 0AK11 20001 To order parts visit us online at http store zephyronline com or call us at 1 888 880 8368 List of Parts and Accessories ...
Страница 22: ...all labor costs associated with this warranty Limitations of Warranty OUR OBLIGATION TO REPAIR OR REPLACE AT OUR OPTION SHALL BE YOUR SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY WE SHALL NOT BE LIABLE FOR INCIDENTAL CONSE QUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH THE USE OR PERFORMANCE OF THE PRODUCTS THE EXPRESS WARRANTIES IN THE PRECEDING SECTION ARE EXCLUSIVE AND IN LIE...