background image

Specifications 

 

 

Care@Home™ Emergency Pendant User Guide 

 

5.

 

Specifications 

 

Category 

Specifications 

Requirements 

Electrical 

Power Supply 

Internal (not replaceable) Lithium 3 V CR2025 

Voltage and Current Ratings 

Nominal voltage: 2.8 V 
Standby time current consumption (@2.8 V): 0.1µA 
Maximum current consumption (@2.8 V): 47mA 

Nominal Battery Life 

Up to 7 years 

NOTE: 

Nominal battery life is computed according to 

Essence's standard usage parameters. 

Wireless 

Bi-directional 

End-to-End Bi-Directional ESI protocol 

Modulation and Frequency 

FSK modulation, 869.225 MHz in Europe and 916.5 MHz in 
America (factory configured) 

Nominal Radio Coverage 

400 m (1312 ft.) – Open Air Nominal 

NOTE: 

Nominal RF coverage is tested over LOS free 

space in a low interference environment. 

Encoding 

32-bit ID, over 4 billion combinations 

Environmental 

Water resistance 

IP67 (immersion) 

NOTE: 

IP Rating has not been verified by UL. 

Operating Ambient Temperature Range 

0°C - 49°C (32°F - 120°F) 

Physical 

Dimensions 

53.2 mm (L) x 31.5 mm (W) x 14.5 mm (H) / 2.1 in. (L) x 
1.24  in. (W) x 0.6 in. (H) 

Weight 

16 g / 0.035 lb. (including battery) 
Key-ring accessory – 2 g / 0.0044 lb. 
Plain accessory – 2 g / 0.0044 lb. 
Watch accessory – 8 g / 0.018 lb. 
Pendant accessory – 8 g / 0.018 lb. 

Color 

RAL 9003 - Glossy White 

Compliance 

 

CE, FCC, IC, UL 

 

Содержание Care@Home Emergency Pendant ES700EP

Страница 1: ...Care Home Emergency Pendant User Guide ESUGSC004 Version 1 1 January 2019...

Страница 2: ...mergency Pendant User Guide Table of Contents 1 Overview 3 2 Installation 4 2 1 Pairing with the CP 4 2 2 EP as a Pendant 4 2 3 EP on a Wristband 5 3 Operation 6 3 1 Emergency 6 3 2 Supervision 6 4 Ma...

Страница 3: ...o signal to the Control Panel CP which in turn passes the message to the Monitoring Station The features of the Portable Emergency Button include Fully water resistant IP67 Wireless connectivity with...

Страница 4: ...p in Blue with a circular movement effect 2 Holding the EP move about 50 cm 20 in away from the CP 3 Press the EP button The pairing process can have the following results If the pairing process is su...

Страница 5: ...ncy Pendant User Guide 5 Figure 2 EP as a Pendant 2 3 EP on a Wristband To wear the EP on your wrist attach the EP to the clip on base attached to the supplied wristband as illustrated in Figure 3 bel...

Страница 6: ...m alive message to the CP The frequency of the reporting periods can be configured locally or remotely The EP status reports include Supervision report The EP sends an I m alive message periodically t...

Страница 7: ...st for a long period of time The internal battery is estimated to last for seven years The battery is sealed and cannot be opened for maintenance by the Resident Upon low battery indication from the E...

Страница 8: ...cy FSK modulation 869 225 MHz in Europe and 916 5 MHz in America factory configured Nominal Radio Coverage 400 m 1312 ft Open Air Nominal NOTE Nominal RF coverage is tested over LOS free space in a lo...

Страница 9: ...to you some or all of the above disclaimers exclusions or limitations may not apply to you By using the information contained herein you agree that the laws of the State of Israel without regard to pr...

Отзывы: