Страница 1: ...150SE SMOKE EXEMPT WOODBURNING STOVE INSTALLATION USER INSTRUCTIONS TO BE LEFT WITH THE CUSTOMER UK Ireland GB IE...

Страница 2: ...and ventilation is required As this stove does not exceed 5 0 kW nominal heat output Refer to Building Regulations Document J a purpose provided air vent is not normally required However in certain c...

Страница 3: ...thorised in Regulations and that appliances used to burn solid fuel in those areas other than authorised fuels have been exempted by an Order made and signed by the Secretary of State or Minister in t...

Страница 4: ...s not terminate in a pressure zone see Fig 2 Be free from cracks severe bends voids and obstructions Be connected to this one appliance only New chimneys must be tested in accordance with HETAS requir...

Страница 5: ...Page 5 125 150 SE I01 210318 Fig 1 Ideal Flue Connections Flue box available from www esseparts com Fig 2 Chimney and Flue Performance...

Страница 6: ...g Allow the burning rate to become steady The flue draught reading should now be taken MAXIMUM The air intake can now be opened to allow the stove to burn at maximum rate Give the stove some time for...

Страница 7: ...if the flue draught is too high The flue stabiliser should be Fitted in the same room as the stove The same size as the flue pipe Fitted no closer than 700mm to the flue outlet of the appliance DIMENS...

Страница 8: ...onnection To change to rear connection the flue collar must be moved from the top flue outlet to the rear outlet To do this the following instructions must be followed 1 Remove the firebricks from the...

Страница 9: ...Check the appliance for sound of seals between castings and main components and that all supplied parts and fitting are correctly fitted On completing the installation check that all the internal comp...

Страница 10: ...ING LIGHTING CONTROLLING THE FIRE Before lighting the fire for the first time ensure that the baffle side and back bricks and all the internal components are in position Burning without either will re...

Страница 11: ...temperature of the flue gases 115 C 245 C 240 F 475 F The flue gases should be in this temperature band for the safest most efficient and most economical operation of your stove Below 115 C This is b...

Страница 12: ...ways This build up of tar is a hazard and if it ignites may cause a chimney fire Resinous softwood burns well and gives a high output for short periods but is not as efficient and does not last as lon...

Страница 13: ...container before starting to paint The door glass is made of a special heat resisting ceramic and may be cleaned when cold with proprietary glass cleaning liquids and a dry cloth SHUTTING DOWN THE STO...

Страница 14: ...ks and baffle plate HOW TO PROCEED WITH A COMPLAINT If you have cause for dissatisfaction with your stove you should first contact your ESSE dealer who will bring your concerns to our attention We wil...

Страница 15: ...Page 15 125 150 SE I01 210318...

Страница 16: ...Page 16 125 150 SE I01 210318 ESSE Engineering Limited Ouzledale Foundry Long Ing Barnoldswick Lancashire BB18 6BN Tel 01282 813 235 Fax 01282 816 876 Website and On line Store http www esse com...