Alarm system for elevators 

compliant with the European Standard  

EN 81-28:2018

 

 
 
 

 

 
 
 

HELPY 2W-xG

  

 
 
 
 
 
 
 

QUICK GUIDE

 

 

 

 
 

 

Содержание Helpy 2W G Series

Страница 1: ...13 01 2020 Alarm system for elevators compliant with the European Standard EN 81 28 2018 HELPY 2W xG QUICK GUIDE...

Страница 2: ...er supply connector C Female DB 9 connector D Termination jumper E Antenna cable connector F Reset pushbutton G Alarm pushbutton H LEDs I SIM card slot with front panel L Serial port for PC connection...

Страница 3: ...els CODE MODEL 5HL 500 Helpy 2W 2G Voice 5HL 510 Helpy 2W 2G Net 5HL 520 Helpy 2W 4G Voice 5HL 530 Helpy 2W 4G Net LEDs Alarm periodical test call yellow Mobile network signal strength green Device st...

Страница 4: ...3 freely programmable factory default filter input IN4 Input 2 4 freely programmable factory default auxiliary input 12 12 Vdc output max 100 mA C3 4 Common terminal 3 for input IN3 and IN4 Negative...

Страница 5: ...ace ATTENTION It is not required to remove the PIN code prior to the use of the Helpy 2W xG The PIN code can be entered if necessary by setting parameter 282 Installing the antenna Screw the antenna e...

Страница 6: ...ssive speaker unit can be connected to each 2W speaker unit The passive speaker unit allows to double the 2W speaker unit voice point and must be installed at max 6 m distance from the 2W speaker unit...

Страница 7: ...er supply input 12 Vdc Negative AR Received alarm indicator light light positive pole AI Given alarm indicator light light positive pole AR Received alarm indicator light light negative pole AI Given...

Страница 8: ...ing the microphone of a passive speaker unit or a single microphone Negative H Microphone DIP switch The DIP switch allows to assign an ID 01 16 to each 2W speaker unit connected to the bus Note it is...

Страница 9: ...TING THE EMERGENCY CALL BUTTONS It is possible to connect external pushbuttons voltage free contact pushbuttons or powered pushbuttons to 2W speaker units Connect following one of the diagrams shown b...

Страница 10: ...to indicate the beginning of the alarm procedure The RECEIVED ALARM INDICATOR LIGHT green switches on when the alarm call is answered Some 2W speaker unit models come with built in indicator lights I...

Страница 11: ...rence IN3 external reference Note if a 2W speaker unit is installed in the cabin it is possible to use the terminal block s filter input of the speaker unit AUX and terminal blocks CONNECTING THE RELA...

Страница 12: ...Page 12 WIRING DIAGRAMS WIRING DIAGRAMS WIRING DIAGRAM WITH 2W SPEAKER UNIT IN THE PIT AND PASSIVE SPEAKER UNIT ON CAR TOP...

Страница 13: ...WIRING DIAGRAMS Page 13 WIRING DIAGRAM WITH LANDING FLOORS...

Страница 14: ...handset and dial Make an external call to check the telephone line is properly working dial and after the Correct message digit the telephone number to make a test call 2 TESTING THE ALARM PROCEDURE...

Страница 15: ...y default Press to end the alarm 2nd mode automatic reset Hang up or press to end the alarm 3nd mode automatic reset with local acknowledgement Hang up to end the call Close the reset input or press t...

Страница 16: ...terrupt an alarm call By pressing shortly you get the same result as lifting the handset of the local telephone and entering Password Pressing longer 10 seconds Allows to reset the device By pressing...

Страница 17: ...RD factory default EXITING THE PROGRAMMING INSTALLER or OPERATOR PASSWORD factory default TELEPHONE NUMBERS INST the programming of the telephone number automatically activates the alarm call position...

Страница 18: ...SDAY THURSDAY FRIDAY SATURDAY TIME INST hhmm from 0000 to 2359 RECORD MESSAGES INST identification message max 25s record hang up courtesy message max 25 s LISTEN TO MESSAGES INST OPER identification...

Страница 19: ...bled EN 81 28 2004 Make a test call manually PROTOCOLS IDENTIFICATION CODE INST Esse ti identification code P100 SPEAKER UNITS VOLUME INST OPER speaker unit ID from 01 to 16 loudspeaker from 1 to 9 fa...

Страница 20: ...rm IN3 gong IN4 filter IN1 alarm IN2 aux IN3 gong IN4 filter IN1 alarm IN2 reset IN3 filter IN4 aux IN1 aux IN2 reset IN3 gong IN4 filter IN1 aux IN2 reset IN3 alarm IN4 alarm IN1 alarm IN2 reset IN3...

Страница 21: ...ed alarm 2W SPEAKER UNIT CONNECTION FAILURE ALARM INST disabled alarm enabled alarm SIM CARD EXPIRING ALARM INST months from 01 to 30 00 disabled alarm FILTER ACTIVATION INST OPER disabled enabled FIL...

Страница 22: ...tic reset alarm reset by End alarm code automatic reset with local acknowledgement PLAY IDENTIFICATION MESSAGE CODE INST from 1 to 3 digits factory default 5 COMMUNICA TION ACTIVATION CODE INST from 1...

Страница 23: ...ICAL ALARMS AND TEST CALLS INST cycles from 1 to 9 0 10 cycles factory default 3 WAITING TIME BETWEEN TECHNOLOGICAL OR TEST CALLS INST minutes from 01 to 99 00 30 seconds factory default 02 AUTOMATIC...

Страница 24: ...lure active for low battery RELAY INTERMITTENCE INST Relay steady state intermittent 500 ms ON 500 ms OFF DTMF GENERATOR SETTING INST DTMF generated by mobile network DTMF generated by Helpy 2W xG DTM...

Страница 25: ...THE BATTERY LEVEL INST expressed in mV LISTEN TO THE EXTERNAL POWER SUPPLY LEVEL INST expressed in mV TEST OF ALARMS INST emergency call button battery alarm periodic automatic test call 2W speaker un...

Страница 26: ...essages of the Helpy 2W xG set a micro SD card to use for programming customizing the messages and updating the firmware of the Helpy 2W xG e stant can be downloaded at the following link https www es...

Страница 27: ...ss to programming and the programming codes to be performed The message format must be as follows Et he xxx c c c c Where Et he is the start of the programming string xxx is the password string defaul...

Страница 28: ...NVERSATION WITH THE SPEAKER UNITS CABIN SPEAKER UNIT ID 01 SPEAKER UNIT ID 02 SPEAKER UNIT ID 03 SPEAKER UNIT ID XX 04 16 DEACTIVATE ALL EXTERNAL CALLS TELEPHONE NUMBER DOOR OPENER RELAY Use remotely...

Страница 29: ...of the programming and functions below can now be performed USE REMOTELY WITH HELPY 2W xG AT REST PROGRAMMING CONVERSATION WITH THE SPEAKER UNITS CABIN SPEAKER UNIT ID 01 SPEAKER UNIT ID 02 SPEAKER U...

Страница 30: ...l test call yellow Emergency call alarm Emergency call alarm suspended Other alarms Test call LED signalling mobile network signal strength green No signal Low signal level connection not guaranteed M...

Страница 31: ...g device status red Normal operation no alarm Alarm Voice connection Battery disconnected or low battery max 1 hour operation in idle state 2W speaker unit connection error or bus problem Absence of t...

Страница 32: ...the battery has low capacity charge The external power supply is connected and the battery is either disconnected or dead The external power supply is disconnected and the battery guarantees more tha...

Страница 33: ...test call notification EN 81 28 2018 The Given alarm indicator light and the Received alarm indicator light flash in opposition to indicate the failure of the automatic test call The flashing sequence...

Страница 34: ...the EU declaration of conformity is available from the following Internet address https www esse ti it en eu declaration of conformity Information to be provided with the lift The information EN 81 28...

Страница 35: ...NOTE Page 35...

Страница 36: ...Esse ti S r l Via G Capodaglio 9 62019 Recanati MC ITALY Tel 39 071 7506066 Fax 39 071 7506057 www esse ti it support esse ti it...