KK-EPA.004 Rev No:0 28.09.18
15
6.4.4. Offset Value
If you want to add offset to the entered set value, this menu is used. All set values are, as much as ofset
value is shifted forward and if it is selected negative then it is shifted backwards .
6.4.5. Default Status Of The Relay (Cond)
Depending on the factory settings of your device, the relay is normally off, so you can change it as normally
open. Use the Cond option to do this. The factory setting NC (Normally Closed) indicates that the relay is
normally closed, NO. (Normally Open) indicates that the relay is normally open.
OUT
0
30
30.
30
The decimal point starts
flashing. Use the UP and DOWN
buttons to select the decimal
digit point.
Press and hold the UP button to move to the
next step.To enter a negative (-) value, move
to one of the non-digit digits and press the
DOWN button.
When you press and
hold to the PRG key ,
the value in the
second line starts
blinking. Enter the
desired value using
the UP and DOWN
* You can also set other relay outputs in the same
way.
bağlantıları:
Press and hold the PRG button.
OUT - 1
OFSET
30
The new offset value you confirmed with the PRG button has
been set. You can return to run mode with the ESC button.
ofset
0
OUT
nc
no
When you press and hold
to the PRG key , the
value in the second line
starts blinking. Enter the
desired value using the
UP and DOWN
Press and hold the PRG button.
OUT - 1
cond
no
The new relay condition you confirmed with the PRG button has
been set. You can return to run mode with the ESC button.
cond
nc
* You can also set other relay outputs in the same
way.