background image

 

                                                
 

Art. No. 11165 

 

All rights reserved. Reproduction as well as electronic duplication of this user guide, complete or in part, requires the written consent of 
ESERA GmbH. Errors and technical modification subject to change. 



ESERA GmbH 2021 

www.esera.de 

11165 V1.0 R1.1 Manual 

Page 1 of 8 

 

User Guide 

 

MSP 120   

 

1-Wire Multisensor Pro II 

 

Professional in-wall Room Sensor for  

Temperature, Air Humidity and Air Quality (VOC) 

 

 

 

Professional in-wall mounted Multisensor for  

o

  Temperature 

o

  Air Humidity 

o

  Air Quality (VOC) 

 

For commercial and residential applications, 
smart building, smart home, schools, public 
buildings and companies 

 

High accuracy Sensors with 12bit resolution 

 

Air Quality Sensor (VOC) with short warm-up 
time and fine resolution at low power 
consumption 

 

Universal in-wall mounting 

 

Shapely and high quality sensor housing 

 

Simple 5VDC power supply  
 

Application 

 

Multisensor for heating control  
(single room control) 

 

Air Humidity Sensor for mold prevention  

 

Air Quality Sensor for control of ventilation systems 

 

Indoor air quality warning and monitoring with bad air  
prevention 

 
 

 

 

Note 

Before you start assembling the device and put the product into operation, please read these 
operating instructions carefully to the end, especially the section of the safety instructions.  
 
 

Содержание 1-Wire Multisensor Pro II

Страница 1: ...tial applications smart building smart home schools public buildings and companies High accuracy Sensors with 12bit resolution Air Quality Sensor VOC with short warm up time and fine resolution at low power consumption Universal in wall mounting Shapely and high quality sensor housing Simple 5VDC power supply Application Multisensor for heating control single room control Air Humidity Sensor for m...

Страница 2: ...ng a ventilation system In combination with 1 Wire ESERA Switching modules binary outputs a very effective and energy saving heating control single room control is possible The 1 Wire Multisensor Pro II is intended for use in normal living spaces For outdoor use and in damp rooms such as sauna steam bath or winter garden a suitable sensor is available via the ESERA website The 1 Wire Multisensor P...

Страница 3: ... of time and therefore money when searching for a 1 Wire device o Classes Assignment ESERA 1 Wire devices are assigned to OWD classes with the same properties This assignment enables fully automatic visualization and data evaluation in control systems A class list is available from ESERA For further information about the ESERA Auto E Connect system please refer to the ESERA website and the ESERA C...

Страница 4: ...50090 2 2 EN 61000 4 2 ESD EN 61000 4 3 HF EN 61000 4 4 Burst EN 61000 4 5 Surge EN 61000 6 1 interference immunity EN 61000 6 3 interference radiation RoHS REACH 7 Software control The 1 Wire Multisensor Pro II is read out via 1 Wire command for DS2438 devices The Multisensor is supported in many controllers such as ESERA Station Loxone IP Symcon OWFS FHEM Linux or microcontroller applications Fo...

Страница 5: ...ebsite at Kompatible Steuerungen Zentralen IP Symcon Integration https www esera de kompatible steuerungen zentralen ip symcon integration For the conventional connection via 1 Wire Bus Coupler the sensor values have to be calculated according to the given formulas 10 Integration in Loxone Via the shop we provide a sample project for reading in the 1 Wire Multisensor via 1 Wire controller 1 1 Wire...

Страница 6: ... Wire Network Cabling The special feature of the 1 Wire system is the BUS technology All devices sensors and actuators are operated in parallel on a three wire line which is used for both power supply and data communication The 1 Wire bus system joins the list of other successful bus systems such as CAN or Modbus RTU All of the installation principles recommended for these are also applicable and ...

Страница 7: ...collection local collection points for electronic waste 20 Safety instructions When handling products that come into contact with electrical voltage the applicable VDE regulations must be observed in particular VDE 0100 VDE 0550 0551 VDE 0700 VDE 0711 and VDE 0860 All final or wiring work must be carried out with the power turned off Before opening the device always unplug or make sure that the un...

Страница 8: ... or gross negligence Claims made under the Product Liability Act are not affected If defects occur for which ESERA GmbH is responsible and in the case of replacement goods the replacement is faulty the buyer has the right to have the original purchase price refunded or a reduction of the purchase price ESERA GmbH accepts liability neither for the constant and uninterrupted availability of the ESER...