User Guide 

1-Wire Multisensor Pro for 

Temperature and Air Humidity 

 
 

 

Professional temperature- and humidity-sensor 
for private, schools,  
public buildings and companies  

 

Precise temperature- and humidity-sensor with 
12Bit resolution 

 

Universal on-wall mounting 

 

Stylish and high quality sensor housing 

 

Easy voltage supply (5VDC) 

 

Application: 

 

Heating control (control of individual rooms) 

 

Control sensor for ventilation system  

 

Monitoring of living areas for risks of mould 

 
 

 

Introduction 

Before you start assembling the 1-Wire Multisensor Pro and before you take the device into operation, please 
read this assembly and operating instruction carefully to the end, especially the section referring to the safety 
notes. 
 

Product description 

With the ESERA 1-Wire Multisensor Pro you have acquired a professional and highly accurate multi-sensor. 
Due to the new technology of the ESERA 1-Wire Pro sensors, the accuracy of humidity measurements is on 
average 200 

– 300 % higher compared to most standard sensors on the market. 

Due to the use of highly integrated sensors with 12-bit resolution, the 1-Wire Multisensor delivers very 
accurate values for temperature and relative humidity. In addition, the evaluation of the delivered measured 
values is enormously simplified. 
The 1-Wire Multisensor Pro enables easy climate monitoring of all rooms and buildings. 
 
The 1-Wire Multisensor Pro is installed in a stylish wall-mounted housing and fits perfectly in modern living 
and business areas.  
Due to the wide ventilation openings, the 1-Wire Multisensor Pro detects climatic conditions in rooms and 
buildings very exactly and quickly. For all types of radiator and heating control, an accurate temperature 
sensor, as installed in this Multisensor, is an important component. 
In combination with 1-Wire ESERA switching modules / binary outputs, a very effective and energy-saving 
heating control (individual room control) is possible. 
The 1-Wire Multisensor Pro is intended for use in normal living spaces. For outdoor use and in damp rooms, such 
as saunas or steam baths, a matching sensor is available on the ESERA website. 
Calibration of the sensors is not necessary. The 1-Wire Multisensor Pro can be put into operation immediately 
without any waiting time. 
The electrical connection to the 1-Wire bus system of the 1-Wire Multisensor Pro is carried out with screwless 
push-in terminals and can be operated in standard mode, 3 cables for ground, data and 5V. 
Each 1-Wire Multisensor Pro has an individual serial number. 

Содержание Multisensor Pro 11150

Страница 1: ... on the market Due to the use of highly integrated sensors with 12 bit resolution the 1 Wire Multisensor delivers very accurate values for temperature and relative humidity In addition the evaluation of the delivered measured values is enormously simplified The 1 Wire Multisensor Pro enables easy climate monitoring of all rooms and buildings The 1 Wire Multisensor Pro is installed in a stylish wal...

Страница 2: ...apacitive digital humidity sensor with high accuracy Range of measuring hum 0 100 rel humidity Accuracy humidity 3 in the range of 10 85 rel humidity Data output 0 10V equates 0 100 rel humidity 0 1V 1 rF Interface 3 wire connection data ground and 5V parasitic operation not supported Connection Push in clamps for cable solid 0 2 to 2 5qmm or finely stranded 0 2 to 1 5qmm For connection we recomme...

Страница 3: ...found in the latest available documentation for 1 Wire Controller 1 Wire Gateway 9 Integration in IP Symcon ESERA Station Through our website we provide ESERA IP Symcon software modules to import the 1 Wire Multisensor in IP Symcon via 1 Wire Controller 1 Wire Gateway Therefore no scripts are necessary Further details can be found here https www esera de kompatible steuerungen zentralen ip symcon ...

Страница 4: ...re advantage of cabling with CAT cable is that a linear bus topology can be achieved despite star shaped cable routing in buildings This is only possible with the 8 core cable construction of a CAT cable We recommend a linear topology When using CAT7 cables the maximum possible cable length of the entire 1 Wire network is reduced due to the stronger shielding and the resulting higher cable capacit...

Страница 5: ...ests according to DGUV regulation 3 German statutory accident insurance https en wikipedia org wiki German_Statutory_Accident_Insurance must be carried out 19 Warranty ESERA GmbH guarantees that the goods sold at the time of transfer of risk to be free from material and workmanship defects and have the contractually assured characteristics The statutory warranty period of two years begins from dat...

Отзывы: