background image

 
 

Art. No. 11132 Gen2 

 

All rights reserved. Reproduction as well as electronic duplication of this user guide, complete or in part, requires the written consent of 
ESERA GmbH. Errors and technical modification subject to change. 



ESERA GmbH, ESERA-Automation 2020 

www.esera.de 

11132 V2.0 R1.0  Manual 

Page 1 of 5 

 

User guide 

1-Wire Multisensor  

Flush-mounted living area sensor 

 
 
 

 

 Temperature sensor 

 

 Precise Humidity sensor 

 

 Suitable for all 55mm switch ranges,  

 

 e.g. Berker, Jung, Busch-Jaeger and many others 

 

 Connection via screwless pressure clamps 

 

 Simple power supply (5V)  

 

 Integrated voltage monitoring 

 

 Simple installation in 55mm flush-mounted boxes 

 

 Orifices (central plates) in pure white matt and glossy available 

 

 

Application 

 

Heating control (individual room control) 

 

Ventilation system control 

 

 

 

 
 

 Introduction 

Before you start installing and commissioning the Multisensor, read this 
manual carefully until the end, especially the section on safety 
instructions. 
This Multisensor is a further development of the previous Multisensors 
11132. The electronics of the integrated brightness sensor have been 
optimised.  

 

 

 Product description 

With the flush-mounted 1-Wire Multisensor, simple monitoring of the 
room climate is possible. The Multisensor is installed in an attractive  
flush-mounted housing and blends harmoniously into modern living  
and business rooms. It can be used for all switch series with  
standard 50/55mm central plate. The cover (central plate) is available 
 in pure white matt and glossy. 
Thanks to the generous ventilation openings, the 1-Wire Multisensor  
very directly and quickly detects the climatic conditions in rooms. 
For all types of radiator and heating controls, an accurate temperature sensor 
is an important actual value transmitter, which is included in the  
1-Wire Multisensor. In combination with 1-Wire ESERA switching  
modules / binary outputs, a very effective and energy-saving heating control  
(individual room control) is possible. The 1-Wire Multisensor is intended  
for use in the interior of residential and business premises. A light sensor  
is integrated for brightness control. The measuring range is adapted to indoor 
areas. 
A calibration of the 1-Wire Multisensor is not necessary. You can put  
the 1-Wire Multisensor into operation immediately without waiting.  

 

 

Note: Cover not part of base article 

Содержание Multisensor 11132 Gen2

Страница 1: ...rated brightness sensor have been optimised 2 Product description With the flush mounted 1 Wire Multisensor simple monitoring of the room climate is possible The Multisensor is installed in an attractive flush mounted housing and blends harmoniously into modern living and business rooms It can be used for all switch series with standard 50 55mm central plate The cover central plate is available in...

Страница 2: ...ates on cold surfaces There is a risk of mold growth here 4 Software Control The 1 Wire Multisensor is read by 1 Wire command for DS2438 devices and is supported by many computer programs like Loxone SPS WAGO SPS via OWOS OWFS FHEM Linux IP Symcon or microcontroller applications 5 Technical data 1 Wire interface DS2438 Multisensor for temperature humidity brightness and operating voltage Measuring...

Страница 3: ... a distinction from the previous 1 Wire Multisensors 11132 before 2019 article number 11133 has been assigned to the new library Data output 1_EVT 12 27 40 1_OWD1_1 2008 Controller No _Module no _Data set Temperature C Example 20 08 C 1_OWD1_2 511 Controller No _Module no _Data set Voltage VCC V 1_OWD1_3 4300 Controller No_ Module no _Data set Air humidity rH Example 43 0 1_OWD1_4 1200 Controller ...

Страница 4: ...E 0860 All final or wiring work must be carried out with the power turned off Before opening the device always unplug or make sure that the unit is disconnected from the mains Components modules or devices may only be put into service if they are mounted in a contact proof housing During installation they must not have power applied Tools may only be used on devices components or assemblies when i...

Страница 5: ...nce Claims made under the Product Liability Act are not affected If defects occur for which the ESERA GmbH responsible and in the case of replacement goods the replacement is faulty the buyer has the right to have the original purchase price refunded or a reduction of the purchase price ESERA GmbH accepts liability neither for the constant and uninterrupted availability of the ESERA GmbH or for te...

Отзывы: