Connector Assignments
4. Connector Assignments
4.1 24V-Power Supply Voltage
The power supply voltage can be fed via connector 24V (X1) or optional via InRailBus (connector
assignment see page 29).
4.1.1 Connector Assignment
Device connector:
Phoenix Contact MSTBO 2,5/4-G1L-KMGY
Line connector:
Phoenix Contact FKCT 2,5/4-ST, 5.0 mm pitch,
spring-cage connection,
Phoenix Contact order No.: 19 21 90 0 (included in the scope of delivery)
For conductor connection and conductor cross section see page 37.
Pin Position:
Pin Assignment:
Labelling on the
CAN-CBX-CPU5201
24 V
M
P
Labelling on the connector
-
+
Pin
1
2
3
4
Signal
Do not
connect!
Do not
connect!
M24
(GND)
P24
(+ 24 V)
Please, refer also to the connecting diagram on page 9.
Attention!
It is
not permissible
to feed through the power supply voltage through the 24V
connector and to supply the power supply voltage to another CAN module station!
A feed through of the +24 V power supply voltage can cause damage on the modules.
Signal Description:
P24... power supply v24 V
M24... reference potential