Interfaces and Connector Assignments
8. Interfaces and Connector Assignments
8.1 24 V-Power Supply Voltage
The power supply voltage can be fed via connector X1 or optional via InRailBus (connector
assignment see page 86)
Device socket:
Phoenix Contact MSTBO 2,5/4-G1L-KMGY
Line connector:
Phoenix Contact FKCT 2,5/4-ST, 5.0 mm pitch,
spring cage connection,
Phoenix Contact order No.: 19 21 90 0 (included in the scope of delivery)
Pin Position:
Pin Assignment:
Labelling of
the
CAN-EtherCAT
24V
.
.
M
P
Connector label
(free)
(free)
-
+
Pin-Nr.
1
2
3
4
Signal
P24
(+ 24 V)
M24
(GND)
M24
(GND)
P24
(+ 24 V)
Please refer to the connecting diagram page 11.
The pins 1 and 4 are connected internally.
The pins 2 and 3 are connected internally.
NOTICE
Feeding through the +24V power supply voltage can cause damage on the modules.
It is not permitted to feed through the power supply voltage through the connector X1 and
to supply the power supply voltage to another CAN module station!
Signal Description:
P24... power supply v24 V ± 10 %
M24... reference potential
Page 68 of 92
Manual • Doc. No.: C.2922.21 / Rev. 1.4
CAN-EtherCAT