Technical Data
4.6 Interfaces available at CAN-USB/400-IRIG-B only
INFORMATION
The IRIG-B option is only available on CAN-USB/400-IRIG-B (C.2069.06).
4.6.1 IRIG-B Interface
Number of inputs
1x analog (IRIG-B_RX+, IRIG-B_RX-)
1x digital (IRIG-B_A+, IRIG-B_A-)
Standard
IRIG-B inputs acc. to standard 200-87,
format B122 (analog) and B003 (digital)
Electrical isolation
both inputs are electrically isolated
Connector
15-pin DSUB, female
Table 7:
Data of the IRIG-B interface
4.6.2 Sync I/Os
Number of I/Os
2 (SYNC1+/-, SYNC2+/-)
Interface
RS-485 trigger channels,
programmable as input or output
Evaluation
timestamp synchronisation of CAN-USB/400-IRIG-B modules
Electrical isolation
none
EMC / conformity
This interface is not examined with regard to the electromagnetic
compliance and immunity. This interface is for custom built evaluation kits
destined for professionals to be used solely at research and development
facilities for such purposes.
Connector
15-pin DSUB, female
Table 8:
Data of the Sync I/Os
4.6.3 Miscellaneous I/Os
Number of I/Os
6 (TRIG0...TRIG5)
Interface
3.3 LVTTL level,
programmable as input or output
Evaluation
digital I/Os, e.g. trigger inputs for CAN Error Injection
Electrical isolation
none
EMC / conformity
This interface is not examined with regard to the electromagnetic
compliance and immunity. This interface is for custom built evaluation kits
destined for professionals to be used solely at research and development
facilities for such purposes.
Connector
15-pin DSUB, female
Table 9:
Data of the Miscellaneous I/Os
CAN-USB/400 / -IRIG-B / -FD
Hardware Manual • Doc. No.: C.2069.21 / Rev. 1.4
Page 15 of 34