Safety Instructions

!

When working with CPCI-COM4 follow the instructions below and read the manual carefully to protect 
yourself from injury and the CPCI-COM4 from damage.

!

Protect the CPCI-COM4 from dust, moisture and steam. 

!

Protect the CPCI-COM4 from shocks and vibrations.

!

The CPCI-COM4 may become warm during normal use. Always allow adequate ventilation around the 
CPCI-COM4 and use care when handling.

!

Do not operate the CPCI-COM4 adjacent to heat sources and do not expose it to unnecessary thermal 
radiation. Ensure an ambient temperature as specified in the technical data.

Attention !
Electrostatic discharges may cause damage to electronic components. 

To avoid this, please perform the steps described on page 8 

before

 you touch the CPCI-COM4, 

in order to discharge the static electricity from your body.

Qualified Personal

This documentation is directed exclusively towards personal qualified in control and automation engineering. 
The installation and commissioning of the product may only be carried out by qualified personal, which is 
authorized to put devices, systems and electric circuits into operation according to the applicable national 
standards of safety engineering.

Intended Use

The intended use of the CPCI-COM4 is the operation as serial interface in a CPCI system. 
The   guarantee   given   by   esd   does   not   cover   damages   which   result   from   improper   use,   usage   not   in  
accordance with regulations or disregard of safety instructions and warnings.

!

The CPCI-COM4 is intended for installation in a CPCI-system only.

!

The operation of the CPCI-COM4 in hazardous areas, or areas exposed to potentially explosive materials 
is not permitted.

!

The operation of the CPCI-COM4 for medical purposes is prohibited.

Service Note

The CPCI-COM4 does not contain any parts that require maintenance by the user. The CPCI-COM4 does 
not require any manual configuration of the hardware.

Disposal

Devices which have become defective in the long run have to be disposed in an appropriate way or have to  
be returned to the manufacturer for proper disposal. Please, make a contribution to environmental protection.

Page 4 of 17

Hardware Manual • Doc. No.: I.2328.21 / Rev. 1.0

CPCI-COM4

Содержание C.2026.02

Страница 1: ...L Hardware Manual to Product I 2328 01 CPCI COM4 Hardware Manual Doc No I 2328 21 Rev 1 0 Page 1 of 17 esd electronic system design gmbh Vahrenwalder Str 207 30165 Hannover Germany http www esd eu Fax...

Страница 2: ...product described herein any license under the patent rights of esd gmbh nor the rights of others esd electronic system design gmbh Vahrenwalder Str 207 30165 Hannover Germany Phone 49 511 372 98 0 Fa...

Страница 3: ...1 0 Document History The changes in the document listed below affect changes in the hardware as well as changes in the description of the facts only Revision Chapter Changes versus previous version Da...

Страница 4: ...oduct may only be carried out by qualified personal which is authorized to put devices systems and electric circuits into operation according to the applicable national standards of safety engineering...

Страница 5: ...ral Technical Data 11 5 2 Microprocessor and Memory 11 5 3 Serial Interface 12 5 4 CompactPCI Bus 12 5 5 IRIG B Interface Option 13 5 6 Software Support 13 6 Connector Assignments 14 6 1 4x RS 232 Int...

Страница 6: ...realised due to modular design The protocol is implemented in the FPGA Physical layer connectors are located on a Piggy back for easy design modifications A Software driver is available for QNX Softwa...

Страница 7: ...PCB View with Connectors 2 PCB View with Connectors Figure 2 PCB top view See also page 14 for signal assignment of the COM connector CPCI COM4 Hardware Manual Doc No I 2328 21 Rev 1 0 Page 7 of 17...

Страница 8: ...as well Procedure 1 Switch off your computer and all connected peripheral devices monitor printer etc 2 Discharge your body as described above 3 Disconnect the computer from the mains If the computer...

Страница 9: ...cription LED name in schematic diagram I green IRIG B always off reserved for future application LED223 R green Power optional off CPCI COM4 not ready FPGA not loaded LED224 on CPCI COM4 is ready for...

Страница 10: ...2 green COM2 Traffic off no serial traffic on COM 2 LED220 blinking serial traffic on COM 2 3 green COM3 Traffic off no serial traffic on COM 3 LED222 blinking serial traffic on COM 3 4 green COM4 Tr...

Страница 11: ...optional IRIG B CompactPCI board connector X100 132 pin male connector CompactPCI board connector X101 132 pin male connector X303 reserved for future use Temperature range 0 50 C ambient temperature...

Страница 12: ...itrate up to 307 2 kBaud 4x HDLC RS 422 Software Standard operating system driver Connector 37 pin DSUB Table 5 Data of the serial interface 5 4 CompactPCI Bus Host bus PCI Bus according to PCI Local...

Страница 13: ...nly Controller 8051 microcontroller Connector DSUB37 Table 7 Data of the optional IRIG B interface 5 6 Software Support Device drivers for QNX1 are available Drivers for VxWorks and Windows are availa...

Страница 14: ...Output Input CTS 8 27 DTR Output Input RI 9 28 GND reference potential COM3 Input DCD 10 29 DSR Input Input Rx 11 30 RTS Output Output Tx 12 31 CTS Input Output DTR 13 32 RI Input reference potential...

Страница 15: ...ut RX A 11 30 RX B Input Output TX CLK A 12 31 TX CLK B Output Input RX CLK A 13 32 RX CLK B Input reference potential GND 14 33 TX A Output COM4 Output TX B 15 34 RX A Input Input RX B 16 35 TX CLK A...

Страница 16: ...RTS B 8 27 CTS A CTS B 9 28 GND reference potential COM3 Rx Tx connect externally TX A 10 29 TX B n c RX A 11 30 RX B Rx Tx connect externally RTS A 12 31 RTS B n c CTS A 13 32 CTS B reference potenti...

Страница 17: ...4x RS 485 I 2328 01 Accessories CPCI COM4 QNX QNX object licence For detailed information about the driver availability of your special operating system please contact our sales team I 2328 15 Manual...

Отзывы: