3
B) Detached Tabletop Display Configuration
1. Gently pull the
Display Unit
to detach it from the
Plastic Display Mount
.
Do not remove any screws.
2. Slide the
Plastic Display Mount
into the scale.
C) Wall Mounted Display Configuration
Skip step 3 for D) Standing Mount Display Configuration.
3. Add the
Coiled Extension Cord
to the
Display Cord
.
4. Remove the four
7 mm Screws
from the two
Grey Brackets
located
underneath the
Display Unit
, and save the
7 mm Screws
for step 6.
5. Tuck the
Display Cord
all the way into
Notch A
at the top of the
Vertical
Arm
, and slide the
Vertical Arm
into the
Display Unit
. It will be a tight fit.
Reference the Vertical Arm drawing on page 2 to locate Notch A.
6. Use the four
7 mm Screws
saved from step 4 to fasten the
Vertical Arm
to the
Display Unit
.
Skip step 7 for D) Standing Mount Display Configuration.
7. Attach the two
Wall Mount Screws
to a wall vertically spaced and 4
cm apart on center. Hang the
Vertical Arm
and
Display Unit
on the
two
Wall Mount Screws
.
Pre-drill 1/4 inch diameter holes for the Drywall
Anchors when mounting onto a drywall surface, or 3/32 inch diameter
holes for the Wall Mount Screws alone.
D) Standing Mount Display Configuration
8. Use two
13 mm Screws
to attach the
Metal Display Mount
inbetween
the rubber feet of the
Vertical Arm
. The
Metal Display Mount
should
protrude in the direction the
Display Unit
is facing.
9. To remove the
Plastic Display Mount,
unscrew the four
5 mm Screws
under the scale to remove the two
Black Brackets
.
10. Use the two remaining
13 mm Screws
to attach the
Metal Display Mount
to the underside of the scale where the
Plastic Display Mount
once was.
11. Reattach the two
Black Brackets
to the underside of the scale with the
four
5 mm Screws
.
12. Plug the
Display Cord
into the scale.
Attention!
Save all unused parts for future reconfigurations.
PRODUCT SUPPORT
24/7 Online community support:
http://escali.zendesk.com
Email support:
Phone support:
1-800-467-6408
Содержание R Series