FAULT
COMMON CAUSE
COMMON SOLUTIONS
The lights can be turned on,
however the motor does not
work
Fan switch is broken
Call After Sales Support for further
guidance.
The motor is broken
Both the light and motor do
not work
The fuse is broken
Reset or replace the fuse.
The power supply cord is loose
or disconnected
Reconnect the power supply to the
wall socket.
Oil is leaking
The one-way-valve and exhaust
pipe are not tightly seal
Disassemble the one-way-valve and
seal with a sealant.
There is a leakage between
section and cover
Disassemble the section and seal
with sealant.
The light is not working
The light globes are damaged
or blown
Call After Sales Support for further
guidance.
The is insufficient suction
power or air is not extracted
adequately.
The distance between the
rangehood and the cooktop is
too great.
Have your installer re-adjust the
installation position, ensuring that
the minimum distances are observed
as per the building code and relevant
standards.
Ducting is loose, kinked, too
long or too many bends.
Check that your rangehood has been
ducted correctly and in accordance
with the installation instructions.
The rangehood is no longer in
a horizontal position
The screws or not tight enough
Tighten the screws and level the
rangehood in a horizontal position.
The rangehood is vibrating
against the wall or cupboard
The rangehood undermount is
not fixed correctly.