Edition 040830
-- 25 --
ch25bie1
INSTALLATION
The installation must be executed by a professional.
WARNING!
This product is intended for industrial use. In a domestic environment this product may cause radio
interference. It is the user’s responsibility to take adequate precautions.
Placing
Place the welding power source so that its cooling air inlets and outlets are not obstructed.
Rating plate
The rating plate is located on the underside of the power source.
Mains power supply
Make sure that the welding power source is connected to the correct supply voltage and
that it is protected by the correct fuse rating. The standards for the country in question must
be complied with as regards the mains cable area. A protective earth connection must be
made in accordance with regulations.
Recommended fuse ratings and minimum cable areas
Mains voltage
230 V
¦
10 %, 1--phase
Mains frequency
50 -- 60 Hz
Fuse (delayed--action)
85A 35% duty cycle
120A 20% duty cycle
160A 35% duty cycle
180 A 25% duty cycle
10 A
16 A
20 A
25 A
Mains cable area
3 x 4 mm
2
Welding cable area
25 mm
2
The cable area and fuse rating above comply with Swedish regulations. Use the welding power source
in accordance with the relevant national regulations.